MétaCan
Menu
Back to cohort
Record W2513705877 · doi:10.2106/jbjs.rvw.15.00096

Clinical Impact of Trunnion Wear After Total Hip Arthroplasty

2016· article· en· W2513705877 on OpenAlexaff
Brent A. Lanting, Douglas D.R. Naudie, Richard W. McCalden

Bibliographic record

VenueJBJS Reviews · 2016
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsWestern University
Fundersnot available
KeywordsMedicineFrettingImplantDentistryTotal hip replacementTotal hip arthroplastySurgeryAdverse effectArthroplastyCrevice corrosionFemoral neckCorrosionInternal medicineOsteoporosisMetallurgy

Abstract

fetched live from OpenAlex

Trunnionosis, characterized by corrosion and fretting of the taper, is a well-known entity commonly demonstrated in retrieval specimens. While there have been a number of recent reports regarding the potential for adverse local tissue reactions related to trunnionosis, it remains a relatively infrequent cause for failure of total hip replacement implants. A number of factors, including both biomechanical and bioelectrochemical factors, have a known impact on the development and severity of trunnionosis. Furthermore, specific implant design and material-related factors have been shown to influence the risk of trunnionosis leading to adverse local tissue reactions. Retention of a well-fixed femoral stem, in spite of corrosion of the male taper junction, is acceptable in the majority of cases. A ceramic head, often in combination with a titanium adaptor sleeve, is the most common replacement reported in the current literature to treat trunnionosis. In patients with modular-neck total hip replacements, revision of the femoral stem is likely required if corrosion at the modular neck-stem junction is encountered.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Review · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.005
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.039
GPT teacher head0.370
Teacher spread0.330 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations24
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueJBJS ReviewsSame topicOrthopaedic implants and arthroplastyFrench-language works237,207