MétaCan
Menu
← Back to cohort
Record W2518625604 · doi:10.1118/1.4961789

Poster ‐ 15: Air kerma rate measurements using a cylindrical free‐air ionization chamber on the 05B1‐1 beamline at the Canadian Light Source

2016· article· en· W2518625604 on OpenAlexaboutno aff
Danielle Anderson, Albert Siegbahn, G. Fallone, Brad Warkentin

Bibliographic record

VenueMedical Physics · 2016
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsnot available
Fundersnot available
KeywordsKermaBeamlineIonization chamberDosimetryDosimeterMonte Carlo methodOpticsPhysicsMedical physicsNuclear engineeringMaterials scienceBeam (structure)Nuclear medicineIonizationRadiationIonMedicineEngineering

Abstract

fetched live from OpenAlex

Purpose: The BioMedical Imaging and Therapy (BMIT) beamlines at the Canadian Light Source offer the opportunity for investigating novel imaging and therapy applications of synchrotron radiation. A necessary component in advancing this research, and in progressing toward clinical applications, is the availability of accurate dosimetry that is traceable to a standards institution. However, dosimetry in this setting is challenging. These beams are typically small, non‐uniform, and highly intense. This work describes air kerma rate measurements on a BMIT beamline using a free‐air ionization chamber (FAC). Methods: The measurements were taken at the 05B1‐1 beamline (∼8 – 100 keV) for several beam qualities with mean energies between 20.0 and 84.0 keV. The Victoreen Model 480 cylindrical FAC, with a specially fabricated 0.52 mm diameter aperture, was used to measure air kerma rates. The required correction factors were determined using a variety of methods: tabulated data, measurements, theoretical calculations and Monte Carlo simulations (EGSnrc user code egs_fac). Results: The experimental air kerma rates measured between 0.270 ± 13.6% and 312 ± 2.7% Gy/min. At lower energies (low filtration), the most impactful correction factors were those for ion recombination and for x‐ray attenuation. Conclusions: These measurements marked the first absolute dosimetry performed at the BMIT beamlines. The experimental and Monte Carlo methods developed will allow air kerma rates to be measured under other experimental conditions, provide a benchmark to which other dosimeters will be compared, and provide a reference for imaging and therapy research programs on this beamline.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.065
Threshold uncertainty score0.130

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0070.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.263
Teacher spread0.241 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→