MétaCan
Menu
Back to cohort
Record W2518875664 · doi:10.1161/circep.116.004338

Clinical Experience With the Subcutaneous Implantable Cardioverter–Defibrillator in Adults With Congenital Heart Disease

2016· article· en· W2518875664 on OpenAlexaff
Jeremy P. Moore, Blandine Mondésert, Michael S. Lloyd, Stephen C. Cook, Ali N. Zaidi, Robert H. Pass, Anitha S. John, Frank A. Fish, Kevin Shannon, Jamil Aboulhosn, Paul Khairy

Bibliographic record

VenueCirculation Arrhythmia and Electrophysiology · 2016
Typearticle
Languageen
FieldMedicine
TopicCongenital Heart Disease Studies
Canadian institutionsMontreal Heart Institute
FundersBoston Scientific Corporation
KeywordsMedicineTetralogy of FallotSudden cardiac deathHeart diseaseCardiologyInternal medicineImplantable cardioverter-defibrillatorAsystoleIntracardiac injectionVentriculotomyVentricleSudden deathDouble outlet right ventricleSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: Sudden cardiac death is a major contributor to mortality for adults with congenital heart disease. The subcutaneous implantable cardioverter-defibrillator (ICD) has emerged as a novel tool for prevention of sudden cardiac death, but clinical performance data for adults with congenital heart disease are limited. METHODS AND RESULTS: A retrospective study involving 7 centers over a 5-year period beginning in 2011 was performed. Twenty-one patients (median 33.9 years) were identified. The most common diagnosis was single ventricle physiology (52%), 9 palliated by Fontan operation and 2 by aortopulmonary shunts: d-transposition of the great arteries after Mustard/Senning (n=2), tetralogy of Fallot (n=2), aortic valve disease (n=2), and other biventricular surgery (n=4). A prior cardiac device had been implanted in 7 (33%). The ICD indication was primary prevention in 67% and secondary in 33% patients. The most common reason for subcutaneous ICD placement was limited transvenous access for ventricular lead placement (n=10) followed by intracardiac right-to-left shunt (n=5). Ventricular arrhythmia was induced in 17 (81%) and was converted with ≤80 Joules in all. There was one implant complication related to infection, not requiring device removal. Over a median follow-up of 14 months, 4 patients (21%) received inappropriate and 1 (5%) patient received appropriate shocks. There was one arrhythmic death related to asystole in a single ventricle patient. CONCLUSIONS: Subcutaneous ICD implantation is feasible for adults with congenital heart disease patients. Most candidates have single ventricle heart disease and limited transvenous options for ICD placement. Despite variable anatomy, this study demonstrates successful conversion of induced ventricular arrhythmia and reasonable rhythm discrimination during follow-up.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.103
Threshold uncertainty score0.330

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.255
Teacher spread0.247 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations80
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueCirculation Arrhythmia and ElectrophysiologySame topicCongenital Heart Disease StudiesFrench-language works237,207