MétaCan
Menu
Back to cohort
Record W2520809728 · doi:10.1063/1.4962540

Use of the drift-time method to measure the electron lifetime in long-drift-length CdZnTe detectors

2016· article· en· W2520809728 on OpenAlexaff
A. E. Bolotnikov, G. S. Camarda, E. Chen, R. Gul, V. Dědič, G. De Geronimo, J. Fried, A. Hossain, J. Mackenzie, Luis Ocampo, P.J. Sellin, Saeid Taherion, Emerson Vernon, Ge Yang, U. El-Hanany, R. B. James

Bibliographic record

VenueJournal of Applied Physics · 2016
Typearticle
Languageen
FieldEngineering
TopicAdvanced Semiconductor Detectors and Materials
Canadian institutionsRedlen Technologies (Canada)
FundersBrookhaven National LaboratoryScience and Technology Facilities Council
KeywordsDetectorElectronMeasure (data warehouse)Product (mathematics)PhysicsRange (aeronautics)Function (biology)Work (physics)Electric fieldPlanarComputational physicsOpticsMaterials scienceNuclear physicsMathematicsQuantum mechanicsGeometryComputer science

Abstract

fetched live from OpenAlex

The traditional method for electron lifetime measurements of CdZnTe (CZT) detectors relies on using the Hecht equation. The procedure involves measuring the dependence of the detector response on the applied bias to evaluate the μτ product, which in turn can be converted into the carrier lifetime. Despite general acceptance of this technique, which is very convenient for comparative testing of different CZT materials, the assumption of a constant electric field inside a detector is unjustified. In the Hecht equation, this assumption means that the drift time would be a linear function of the distance. This condition is not fulfilled in practice at low applied biases, where the Hecht equation is most sensitive to the μτ product. As a result, researchers usually take measurements at relatively high biases, which work well in the case of the low μτ-product material, <10−3 cm2/V, but give significantly underestimated values for the case of high μτ-product crystals. In this work, we applied the drift-time method to measure the electron lifetimes in long-drift-length (4 cm) standard-grade CZT detectors produced by the Redlen Technologies. We found that the electron μτ product of tested crystals is in the range 0.1–0.2 cm2/V, which is an order of the magnitude higher than any value previously reported for a CZT material. In comparison, using the Hecht equation fitting, we obtained μτ = 2.3 × 10−2 cm2/V for a 2-mm thin planar detector fabricated from the same CZT material.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.231
Teacher spread0.218 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Applied PhysicsSame topicAdvanced Semiconductor Detectors and MaterialsFrench-language works237,207