Reliability of delivered dialysate sodium concentration

2016· article· en· W2527095806 on OpenAlexvenueno aff
Nasirul Ekbal, Anne Consalus, Jahm Persaud, Andrew Davenport

Bibliographic record

VenueHemodialysis International · 2016
Typearticle
Languageen
FieldMedicine
TopicDialysis and Renal Disease Management
Canadian institutionsnot available
Fundersnot available
KeywordsSodiumFlame photometryMedicineHemodialysisDialysisRepeatabilityChemistryChromatographySurgery

Abstract

fetched live from OpenAlex

Abstract Background The results of studies investigating the effects of hyponatraemic dialysates have been mixed, with some reporting positive effects including reduction in blood pressure and inter‐dialytic weight gains, whereas others have not been able to demonstrate any effect. These studies assume that setting a lower dialysate sodium results in the delivery of a hyponatraemic dialysate. We therefore measured delivered sodium to determine reliability. Methods We measured dialysate sodium in 10 BBraun Dialog+® and 6 Fresenius 4008H dialysis machines, which had been set up to deliver a sodium of 136 mmol/L, using flame photometry and indirect ion selective electrode (ISE) methods. Results Dialysate conductivity was 13.85 ± 0.05 mS/cm, but dialysate sodium measured by flame photometry was 141.8 ± 2.9 mmol/L, and 142.5 ± 2.4 mmol/L by ISE. Both dialysis machines delivered a dialysate sodium in excess of the 136 mmol/L set, with a mean bias of 7.0 ±2.1 mmol/L for the Dialog+®, and 3.7 ± 2.6 for the 4008 with the flame photometer method, and a mean bias of 6.3 ± 1.3 mmol/L for the Dialog+®, and 6.8 ± 3.7 for the 4008 by ISE. Conclusion It is assumed when setting a dialysate sodium concentration that this sodium concentration is delivered. However we found that the dialysate sodium concentration delivered was greater than that set, despite the dialysis machines reporting a conductivity measurement in keeping with a lower sodium dialysate. Trials of lowered dialysate sodium therefore need to measure dialysate sodium concentrations to ensure what has been set is delivered.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.008
metaresearch head score (Gemma)0.020
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.008
Threshold uncertainty score0.044

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0080.020
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.259
Teacher spread0.247 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations24
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueHemodialysis InternationalSame topicDialysis and Renal Disease ManagementFrench-language works237,207