MétaCan
Menu
Back to cohort
Record W2528009051 · doi:10.1111/trf.13859

Comparison of two apheresis systems for autologous stem cell collections in pediatric oncology patients

2016· article· en· W2528009051 on OpenAlexaff
Ehud Even‐Or, Alexandra Eden‐Walker, Maria Di Mola, Elizabeth McDougall, Tal Schechter, Muhammad Ali, Gordana Svajger, Adam Gassas, Christoph Licht, Joerg Krueger

Bibliographic record

VenueTransfusion · 2016
Typearticle
Languageen
FieldMedicine
TopicHematopoietic Stem Cell Transplantation
Canadian institutionsHospital for Sick Children
Fundersnot available
KeywordsMedicineApheresisBlood collectionDemographicsCD34Nuclear medicineSurgeryStem cellUrologyInternal medicinePlateletEmergency medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Peripheral stem cell collections can be challenging in the pediatric population and respective experience is limited. Since February 2015 our institution is utilizing the new Spectra Optia (Optia) apheresis device, which has replaced the former COBE Spectra (COBE) device. As a quality initiative we collected and compared collection efficiency (CE2) and other collection variables between the two devices. STUDY DESIGN AND METHODS: In this retrospective study we collected and compared clinical, laboratory, and technical collection data from stem cell collection procedures done with the Optia and COBE devices. The collected data included patient demographics, precollection peripheral CD34+ cell counts, total CD34+ cells collected, complete blood count, electrolytes before and after collection, side effects attributed to the collection, total blood volumes processed (TBVs), collection times, and calculated CE2 and collection ratios. RESULTS: Forty-one collection procedures performed on 29 pediatric patients with the Optia device were compared to 41 collections performed on 27 patients with the COBE device. The TBVs through the Optia device were significantly smaller than the COBE (3.9 ± 0.2 × TBV vs. 5.5 ± 0.1 × TBV, respectively; p < 0.001), requiring significantly less anticoagulant and providing similar amounts of stem cells while collection times were significantly shorter (mean, 238 ± 9 min vs. 264 ± 9 min, respectively; p < 0.05). Collections on the Optia caused significantly smaller reductions of plasma calcium and magnesium. No significant side effects attributed to the procedure were noted. CONCLUSION: Stem cell apheresis with the Optia device in children is safe and feasible with smaller blood volumes with shorter collection times.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.012
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.016

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.012
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.320
Teacher spread0.289 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations22
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueTransfusionSame topicHematopoietic Stem Cell TransplantationFrench-language works237,207