MétaCan
Menu
Back to cohort
Record W2529208295 · doi:10.1109/nssmic.2015.7581828

Performance characterization of a dual-threshold time-over-threshold APD-based detector front-end module for PET imaging

2015· article· en· W2529208295 on OpenAlexaff
Émilie Gaudin, Louis Arpin, Jonathan Bouchard, Maxime Paillé, Haithem Bouziri, Mélanie Bergeron, C. Pépin, J. Cadorette, Réjean Fontaine, Roger Lecomte

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldPhysics and Astronomy
TopicRadiation Detection and Scintillator Technologies
Canadian institutionsUniversité de Sherbrooke
Fundersnot available
KeywordsDetectorPhysicsScintillatorAvalanche photodiodePixelCalibrationEnergy (signal processing)Lyso-Optics

Abstract

fetched live from OpenAlex

The LabPET II front-end module is an avalanche photodiode (APD) based pixelated detector designed to achieve submillimetric spatial resolution in pre-clinical Positron Emission Tomography (PET). This technology is also based on Time-over-Threshold (ToT) signal processing and designed to be used as a generic platform for ultra-high resolution PET imaging of small and medium-size animals. The basic building block uses a 4×8 array of 1.12×1.12×12 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> Lu <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1.9</inf> Y <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0.1</inf> SiO <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5</inf> :Ce (LYSO) scintillator pixels with one-to-one coupling to a 4×8 pixelated APD array mounted on a ceramic carrier. Four of these detectors are mounted on a PCB with two 64-channel ASICs interfacing to two detector modules each. Signals from each APD pixel can be individually processed by dedicated dual-threshold ToT channels providing timing and energy data. Energy calibration was performed using gamma ray sources in the range 300–1275 keV to correct the non-linearity of the ToT signal and obtain energy spectra. Energy and timing performance of the complete front-end module was evaluated. Results confirm the functionality of the dual threshold ToT circuit implemented in the 64-channel ASIC, as well as the physical performance of the most recent LabPET II version of APD-based detectors for applications in high-resolution PET imaging.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.800
Threshold uncertainty score0.643

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.227
Teacher spread0.214 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2015
Admission routes1
Has abstractyes

Explore more

Same topicRadiation Detection and Scintillator TechnologiesFrench-language works237,207