MétaCan
Menu
Back to cohort
Record W2530908713 · doi:10.1089/lap.2016.0334

Thoracoscopic Lobectomy in Infants and Children Utilizing a 5 mm Stapling Device

2016· article· en· W2530908713 on OpenAlexaff
Steven S. Rothenberg

Bibliographic record

VenueJournal of Laparoendoscopic & Advanced Surgical Techniques · 2016
Typearticle
Languageen
FieldMedicine
TopicCongenital Diaphragmatic Hernia Studies
Canadian institutionsColumbia College
Fundersnot available
KeywordsMedicineSurgeryThoracoscopy

Abstract

fetched live from OpenAlex

PURPOSE: Thoracoscopic lobectomy for congenital cystic lung disease has become an accepted and in many institutions the preferred technique. However, the technical challenges are many. Previous endoscopic staplers (12 mm) used commonly in adults are too large for use in infants This study evaluates the safety and efficacy of using a 5 mm stapling device to seal and divide major pulmonary structures. METHODS: From July 2014 to March 2016, 26 patients of age 6 weeks to 13 months underwent thoracoscopic lobectomy for CPAM or sequestration. Weights ranged from 3.2 to 11.4 kg. There were 7 upper lobectomies, 2 middle, and 17 lower lobectomies. In each case, the 5 mm stapler (Justright Surgical; Louisville, Colorado) was the primary device for vessel and bronchial sealing and division. It is 4.8 mm in diameter with an anvil length of 25 mm and lays down four rows of staples and divides between them. A 3 mm sealing device was used for dissection and to take smaller segmental vessels as necessary. Stump lines were evaluated for bleeding or air leak in all cases. RESULTS: All procedures were accomplished successfully thoracoscopically. The stapler was used on the main lobar artery cases and vein in 24 cases, a large systemic sequestration vessel in 5 cases, and the bronchus in all 26. The stapler was also used to complete the minor fissure in 1 case and the major fissure in 1 case. A total of 96 staple loads were fired. Operative times ranged from 35 to 135 minutes. There was no significant bleeding of any vascular stump. In 1 case, the edge of the bronchial stump had to be reinforced, this was thought to be secondary to too much tissue being enclosed in the jaws. There were no postoperative complications. CONCLUSION: The use of a 5 mm stapling device appears to be safe and effective in thoracoscopic lobectomy in infants. It allows for safe management of major pulmonary vessels and bronchi in the confined chest of an infant through a single 5 mm port.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.425
Threshold uncertainty score0.629

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.319
Teacher spread0.304 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations29
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Laparoendoscopic & Advanced Surgical TechniquesSame topicCongenital Diaphragmatic Hernia StudiesFrench-language works237,207