MétaCan
Menu
Back to cohort
Record W2539723822 · doi:10.1109/nssmic.2011.6152704

Simultaneous <sup>99m</sup>Tc/<sup>111</sup>In SPECT image reconstruction using convolution based forced detection

2011· article· en· W2539723822 on OpenAlexaff
Muhammad I. Karamat, Troy Farncombe

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsHamilton Health SciencesMcMaster University
Fundersnot available
KeywordsSpect imagingIterative reconstructionMonte Carlo methodCrosstalkGamma cameraDetectorComputer scienceSingle-photon emission computed tomographyPhysicsAlgorithmImage resolutionIsotopeImaging phantomNuclear medicineArtificial intelligenceMathematicsOpticsStatisticsNuclear physicsMedicine

Abstract

fetched live from OpenAlex

Simultaneous multi-isotope SPECT imaging has a number of applications, for example, cardiac, brain and cancer imaging. The major concern in simultaneous multi-isotope is the significant crosstalk contamination between the different isotopes used. The current study focuses on a method of crosstalk compensation between two isotopes in simultaneous dual isotope SPECT acquisition applied to cancer imaging using99mTc/111In. Monte Carlo (MC), which is thought to offer the most realistic crosstalk and scatter compensation modeling, in typical implementations, has inherent long calculation times (often several hours or days) associated with it. This makes MC unsuitable for clinical applications. We have previously incorporated convolution based forced detection into SIMIND Monte Carlo program which have made MC feasible to use in clinical time frames. In order to evaluate the accuracy of our accelerated MC program a number of point source simulation results were compared to experimentally acquired data in terms of spatial resolution and detector sensitivity. We have developed an iterative MC-based image reconstruction technique that simulates the photon downscatter from one isotope into the acquisition window of a second isotope. The MC based estimation of scatter contamination contained in projection views is then used to compensate for the photon contamination during iterative reconstruction. We use a modified ordered subset-expectation maximization (OS-EM), named as simultaneous ordered subset-expectation maximization (Sim-OSEM), to perform this step. We have undertaken a number of simulation tests and phantom studies to verify this approach. The proposed reconstruction technique also evaluated by reconstruction of experimentally acquired projection phantom data. Reconstruction using Sim-OSEM showed very promising results in terms of crosstalk and scatter compensation and uniformity of background compared to analytical attenuation based reconstruction after triple energy window (TEW) based scatter correction of projection data. In our case images obtained using Sim-OSEM showed better scatter compensation and more uniform background when compared to the images reconstructed for separately acquired projection data using analytical attenuation based reconstruction.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.006
Threshold uncertainty score0.018

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0060.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.279
Teacher spread0.251 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2011
Admission routes1
Has abstractyes

Explore more

Same topicMedical Imaging Techniques and ApplicationsFrench-language works237,207