MétaCan
Menu
Back to cohort
Record W2544857363 · doi:10.1177/0954411916676508

Biomechanical analysis of the cephalomedullary nail versus the trochanteric stabilizing plate for unstable intertrochanteric femur fractures

2016· article· en· W2544857363 on OpenAlexaff
David Walmsley, Bruce Nicayenzi, Paul R.T. Kuzyk, Alan Machin, Habiba Bougherara, Emil H. Schemitsch, Radovan Zdero

Bibliographic record

VenueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · 2016
Typearticle
Languageen
FieldMedicine
TopicHip and Femur Fractures
Canadian institutionsVictoria HospitalUniversity of TorontoToronto Metropolitan UniversitySt. Michael's HospitalWestern UniversityMount Sinai Hospital
FundersOrthopaedic Trauma AssociationStryker
KeywordsNail plateFemurOrthodonticsNail (fastener)Intramedullary rodMedicineBending of platesMaterials scienceAnatomySurgeryBendingComposite material

Abstract

fetched live from OpenAlex

Unstable intertrochanteric fractures are commonly treated with a cephalomedullary nail due to high failure rates with a sliding hip screw. The Omega3 Trochanteric Stabilizing Plate is a relatively new device that functions like a modified sliding hip screw with a proximal extension; however, its mechanical properties have not been evaluated. This study biomechanically compared a cephalomedullary nail, that is, Gamma3 Nail against the Omega3 plate. Unstable intertrochanteric fractures were created in 24 artificial femurs. Experimental groups were as follows: Nail (i.e. Gamma3 Nail) (n = 8), Plate A (i.e. Omega3 plate with four distal non-locking screws and no proximal locking screws) (n = 8), Plate B (i.e. Plate A plus five proximal locking screws) (n = 8), Plate C (i.e. Omega3 plate with three distal locking screws and no proximal locking screws) (n = 8), and Plate D (i.e. Plate C plus five proximal locking screws) (n = 8). All specimens were stiffness tested, while the Nail and Plate D groups were also strength tested. For lateral bending, Plate B was less stiff than the Nail (p = 0.001) and Plate A (p = 0.009). For torsion, Plate A was less stiff than Plate D (p = 0.020). For axial compression, the Nail was less stiff than Plate A (p = 0.036) and Plate B (p = 0.008). Axial strength for the Nail (5014 ± 308 N) was 66% higher than the Plate D construct (2940 ± 411 N) (p < 0.001). All Nails failed by partial or complete cutout through the femoral head and neck, but Plate D failed by varus collapse and deformation of the lag screw. When the cephalomedullary nail is clinically contra-indicated, this study supports the use of the Omega3 plate, since it had similar stiffness in three test modes to the Gamma3 Nail, but had lower strength. Stability of Omega3 plate constructs was not improved with locked fixation proximally or distally.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.276
Teacher spread0.255 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in MedicineSame topicHip and Femur FracturesFrench-language works237,207