MétaCan
Menu
Back to cohort
Record W2547567972 · doi:10.1161/circep.112.970798

Use of Primary Prevention Implantable Cardioverter-Defibrillators in a Population-Based Cohort Is Associated With a Significant Survival Benefit

2012· article· en· W2547567972 on OpenAlexaff
Ratika Parkash, John L. Sapp, Magdy N. Basta, Steve Doucette, Kara Thompson, Martin J. Gardner, Chris Gray, Brenda Brownell, Hena Kidwai, Jafna L. Cox

Bibliographic record

VenueCirculation Arrhythmia and Electrophysiology · 2012
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsQueen Elizabeth II Health Sciences CentreDalhousie University
Fundersnot available
KeywordsMedicineImplantable cardioverter-defibrillatorCohortHazard ratioPopulationSudden cardiac deathRetrospective cohort studyInternal medicineCohort studyPrimary preventionEmergency medicineConfidence intervalDisease

Abstract

fetched live from OpenAlex

BACKGROUND: Underuse of implantable defibrillators has been previously noted in patients at risk for sudden cardiac death, as well as for survivors of sudden cardiac death. We sought to determine the utilization rates in a primary prevention implantable cardioverter-defibrillator (ICD)-eligible population and mortality in this group compared with a group that had undergone implantation of this therapy. METHODS AND RESULTS: A retrospective cohort of patients from April 1, 2006, to December 31, 2009, was used to define a primary prevention ICD-eligible population. Two groups were compared on the basis of ICD implantation (no-ICD versus ICD). The primary outcome measure was mortality. Of the 717 patients found to be potentially eligible for a primary prevention ICD, 116 (16%) were referred. The remaining cohort of 601 patients were compared with an existing cohort of primary prevention ICD patients (n=290). A significant survival benefit was associated with primary prevention ICD implantation (hazard ratio, 0.46; 95% CI [0.33-0.64]; P<0.0001). When adjusted for prespecified variables known to be associated with overall mortality and propensity score, a similar survival benefit was seen (hazard ratio, 0.59; 95% CI [0.40-0.87]; P=0.01). Appropriate ICD therapy occurred in 26% of those in the ICD group, during a mean follow-up of 2.7 years. CONCLUSIONS: A significant mortality benefit was observed for patients who underwent primary prevention ICD implantation compared with those who did not. Vigilance is required to ensure that patients eligible for primary prevention ICDs are appropriately referred and assessed to allow such patients to benefit from this life-saving therapy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.004
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.250
Teacher spread0.226 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations31
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueCirculation Arrhythmia and ElectrophysiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207