MétaCan
Menu
Back to cohort
Record W2548572495 · doi:10.1109/nssmic.2012.6551726

Application of HDMI<sup>®</sup> cables as an MRI compatible single cable solution for Readout and power supply of SiPM based PET detectors

2012· article· en· W2548572495 on OpenAlexaff
Andrew L. Goertzen, Jonathan D. Thiessen, Xuezhu Zhang, Chenyi Liu, Eric Berg, D. Bishop, Piotr Kozłowski, F. Retière, Vesna Sossi, Greg Stortz, Christopher J. Thompson

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldPhysics and Astronomy
TopicRadiation Detection and Scintillator Technologies
Canadian institutionsMontreal Neurological Institute and HospitalMcGill UniversityUniversity of British ColumbiaTRIUMFUniversity of Manitoba
Fundersnot available
KeywordsSilicon photomultiplierDetectorElectrical engineeringAnalog signalAnalog-to-digital converterPhysicsEngineeringVoltageTransmission (telecommunications)Scintillator

Abstract

fetched live from OpenAlex

All PET detectors require cabling to supply power and transmit data, whether in analog or digital form. In this work we examine using High-Definition Multimedia Interface (HDMI®) cables as a single cable solution to both supply power and transmit analog signals for a SiPM based PET detector that will be used in a hybrid PET/MRI imaging system. HDMI cables are designed for digital audio/video transmission, with each cable having four pairs of shielded 100 ohm differential signal lines, each rated for 3.4 Gbit/s, along with 7 additional signal lines and a braided shield around the entire cable. While designed as a digital signal cable, the lines are rated for 40V DC and 0.5A current. To test using HDMI® cables for application in PET, a silicon photomultiplier (SiPM) PET detector module with a single HDMI® Type C ('mini) receptacle was built using a SensL SPMArray4 coupled to a dual-layer offset LYSO crystal array 1.67 mm crystal pitch. The 16 detector outputs were multiplexed to four signals using a simple resistor charge division network and driven using Analog Devices AD8132 op-amps. Detector bias of 30.2V and +/-5V power for the op-amps was supplied through a 25' length HDMI® cable connected through a custom receiver card. The signals were processed using NIM electronics and digitized with a PC based analog to digital converter (ADC) card. The PET detector had an average energy resolution of 14.3% full-width at half-maximum (FWHM) and an average timing resolution of 2.50 ns. The performance of the PET detector was unaffected when operated inside a 7T MRI system. The MR images showed degradation in signal to noise ratio (SNR) of between 7 and 23%, which is believe to be due to coupling between the RF coil and the PET detector shielding. The results of this work suggest that HDMI® cab

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.767
Threshold uncertainty score0.417

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.245
Teacher spread0.233 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2012
Admission routes1
Has abstractyes

Explore more

Same topicRadiation Detection and Scintillator TechnologiesFrench-language works237,207