MétaCan
Menu
Back to cohort
Record W2551015834 · doi:10.15392/bjrs.v4i2.187

Assessment of whole-body occupational radiation exposure in industrial radiography practices in Bangladesh during 2010-2014

2016· article· en· W2551015834 on OpenAlexaboutno aff
Mohammad Sohelur Rahman, A. Begum, Ashraful Hoque, Rezaul Karim Khan, M. M. Mahfuz Siraz

Bibliographic record

VenueBrazilian Journal of Radiation Sciences · 2016
Typearticle
Languageen
FieldMedicine
TopicRadiation Dose and Imaging
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineDosimeterRadiation protectionThermoluminescent dosimeterRadiographyEffective dose (radiation)Environmental healthNuclear medicineDosimetrySurgery

Abstract

fetched live from OpenAlex

Presently, ten industrial radiography facilities are operating in Bangladesh using X-ray or gamma-ray sources. During the last 5-year, 14 industrial radiography facilities were received individual monitoring service using thermoluminescent dosimeters (TLDs) from the Health Physics Division (HPD), Atomic Energy Centre, Dhaka under Bangladesh Atomic Energy Commission. HPD is the only individual monitoring service provider in Bangladesh due to external sources of ionizing radiation. The number of monitored industrial radiography facilities ranged from 7 to 14 while the number of worker ranged from 72 to 133 during the study period. The annual average effective doses received from external radiation in industrial radiography workers and the distributions of the annual effective doses by dose intervals are presented. The distribution of the occupational doses shows that the majority (about 75 %) of workers received doses below 1 mSv for the last 5-years. Even though, very few workers (about 1%) received doses higher than average annual dose limit (20 mSv), but no workers received doses higher than 100 mSv in 5 consecutive years. The average annual effective dose of industrial radiography workers in Bangladesh is higher than the corresponding values in Tanzania, Greece, Poland, Australia, UK and lower than in Bosnia and Herzegovina, USA and Canada. However, the average annual effective dose is comparable to the corresponding values in China, Brazil, Germany and India. The status and trends in occupational doses show that radiation protection situation at the majority of the workplace were satisfactory. In spite of that, additional measures are required due to big differences observed in the maximum individual doses over the last 5-year.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.036
Threshold uncertainty score0.368

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0020.001
Science and technology studies0.0000.000
Scholarly communication0.0000.002
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.039
GPT teacher head0.354
Teacher spread0.315 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations32
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueBrazilian Journal of Radiation SciencesSame topicRadiation Dose and ImagingFrench-language works237,207