MétaCan
Menu
← Back to cohort
Record W2562180448

Optimization of an Image-guided Radiation Therapy Protocol for Advanced Stage Lung Cancer

2016· dissertation· en· W2562180448 on OpenAlexfundno aff
Peter Hoang

Bibliographic record

VenueMacSphere (McMaster University) · 2016
Typedissertation
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsnot available
FundersMcMaster University
KeywordsLung cancerStage (stratigraphy)Radiation therapyMedicineProtocol (science)Medical physicsRadiologyOncologyAlternative medicinePathologyBiology
DOInot available

Abstract

fetched live from OpenAlex

Image-guided radiation therapy (IGRT) provides accurate and precise tumour targeting. To ensure adequate coverage in IGRT, a planning target volume (PTV) margin is added around the target to account for treatment uncertainties. Treatment plans are designed to deliver a high percentage of the prescription dose to the PTV; thus, portions of healthy tissue are also subjected to high radiation dose. IGRT employs dedicated devices that enable visual assessment of some treatment uncertainties, such as variations in patient set-up. Safe and effective IGRT delivery requires adherence to disease site-specific protocols that describe process details such as imaging technique, alignment method, and corrective action levels. Protocol design is challenging since its effect on treatment accuracy is currently unknown. This thesis aims to understand the interplay between lung IGRT protocol parameters by developing a framework that quantifies geometrical accuracy. Deformable image registration was used to account for changes in target shape and size throughout treatment. Sufficient accuracy was considered when at least 99% of the target surface fell within the PTV. This analysis revealed that the clinical 10 mm PTV margin can be safely reduced by at least 2 mm in each direction. Evaluation of IGRT accuracy was extended to spinal cord alignment. Simulations were carried out with various matching strategies to correct for set-up error, including rotational off-sets. Inappropriate combinations of matching strategies and safety margins resulted in sub-optimal geometrical coverage. Various lung IGRT protocol options were recommended to optimize accuracy and workflow efficiency. For example, an 8 mm PTV margin can be used with spinal cord alignment, a 4 mm cord margin, and up to 5° of rotational error. A more aggressive protocol involved a 6 mm PTV margin with direct target alignment, a 5 mm cord margin, and a 4° rotational tolerance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.304
Teacher spread0.293 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueMacSphere (McMaster University)→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→