Abstract

fetched live from OpenAlex

BACKGROUND: Infiltrations from cannulation result in significant morbidity including loss of hemodialysis (HD) vascular access (VA). Cannulation is dependent on personnel skill and VA characteristics. Surface marking of VA lacks real-time information and traditional ultrasound (US) devices are large, expensive, requiring skilled operators. Sonic Window© (Analogic Ultrasound, Peabody, MA, USA) is a coronal mode ultrasound device (CMUD) approved for VA cannulation. METHODS: Single center randomized, prospective pilot study comparing handheld US-guided cannulation of new arteriovenous fistula (AVF) to standard cannulation practices. Patients with end stage renal disease (ESRD) on in-center HD who had a new AVF cleared for cannulation and dialysis were enrolled. Patients with new AVF received either standard cannulation (control group) or image guidance using CMUD (study group) for 3 weeks. Ultrasound characteristics of VA, cannulation practices and complications end points were obtained. RESULTS: An infiltration rate of 9.7% was noted during the study. Slightly lower odds ratio (OR) of infiltration was observed in the study group (OR 0.94, 95% CI: 0.26-3.41, P value = 0.93). Study group yielded longer time for assessment (101.8 ± 80.2 vs. 22.3 ± 22.5 seconds, P = < 0.001), increased cannulation time (41.1 ± 70.6 vs. 25.0 ± 27.9 seconds, P = 0.04), and increased patient satisfaction (94.6% vs. 82%, P = 0.04) compared to control group. Number of cannulation attempts, needle size, arterial or venous needle insertion, and tourniquet usage between groups were not statistically different. CONCLUSION: Handheld ultrasound is a safe and useful aid in cannulation of dialysis access.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.017

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0030.001
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0050.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.053
GPT teacher head0.391
Teacher spread0.338 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueHemodialysis InternationalSame topicCentral Venous Catheters and HemodialysisFrench-language works237,207