MétaCan
Menu
Back to cohort
Record W2573923702 · doi:10.1002/mp.12023

Experimental verification of 4D Monte Carlo simulations of dose delivery to a moving anatomy

2017· article· en· W2573923702 on OpenAlexaff
Sara Gholampourkashi, M. Vujicic, Jason Bélec, Joanna Cygler, Emily Heath

Bibliographic record

VenueMedical Physics · 2017
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsOttawa HospitalCarleton University
Fundersnot available
KeywordsImaging phantomMonte Carlo methodLinear particle acceleratorDosimetryDICOMVoxelPhysicsNuclear medicineTruebeamRadiation treatment planningSimulationMedical imagingComputer scienceBeam (structure)OpticsRadiation therapyMathematicsMedicineComputer visionArtificial intelligence

Abstract

fetched live from OpenAlex

Purpose To evaluate a novel 4D Monte Carlo simulation tool by comparing calculations to physical measurements using a respiratory motion phantom. Methods We used a dynamic Quasar phantom in both stationary and breathing states (sinusoidal motion of amplitude of 1.8 cm and period of 3.3 s) for dose measurements on an Elekta Agility linear accelerator. Gafchromic EBT3 film and the RADPOS 4D dosimetry system were placed inside the lung insert of the phantom to measure dose profiles and point‐dose values at the center of the spherical tumor inside the insert. Both a static 4 × 4 cm2 field and a VMAT plan were delivered. Static and 4D Monte Carlo simulations of the treatment deliveries were performed using DOSXYZnrc and a modified version of the defDOSXYZnrc user code that allows modeling of the continuous motion of both machine and patient. DICOM treatment plan files and linac delivery log files were used to generate corresponding input files. The phantom motion recorded by RADPOS during beam delivery was incorporated into the input files for the 4DdefDOSXYZnrc simulations. Results For stationary phantom simulations, all point‐dose values from MC simulations at the tumor center agreed within 1% with film and within 2% with RADPOS. More than 98% of the voxels from simulated dose profiles passed a 1D gamma of 2%/2‐mm criteria against measured dose profiles. Similar results were observed when applying a 2D gamma analysis with a 2%/2‐mm criteria to compare 2D dose distributions of Monte Carlo simulations against measurements. For simulations on the moving phantom, MC‐calculated dose values at the center of the tumor were found to be within 1% of film and within 2σ of experimental uncertainties which are 2.8% of the RADPOS measurements. 1D gamma comparisons of the dose profiles were better than 91%, and 2D gamma comparisons of the 2D dose distributions were found to be better than 94%. Conclusion Our 4D Monte Carlo method using defDOSXYZnrc can be used to accurately calculate the dose distribution in continuously moving anatomy for various treatment techniques. This work, if extended to deformable anatomies, can be used to reconstruct patient delivered dose for use in adaptive radiation therapy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.007
Threshold uncertainty score0.013

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.006
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.338
Teacher spread0.321 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations15
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207