MétaCan
Menu
Back to cohort
Record W2583691370 · doi:10.1088/1361-6579/aa513f

Detection of lead in bone phantoms and arsenic in soft tissue phantoms using synchrotron radiation and a portable x-ray fluorescence system

2017· article· en· W2583691370 on OpenAlexafffund
Craig Groskopf, Stephen R. Bennett, Mihai R. Gherase, David Fleming

Bibliographic record

VenuePhysiological Measurement · 2017
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsMount Allison University
FundersNational Research Council CanadaCanadian Institutes of Health ResearchNatural Sciences and Engineering Research Council of CanadaMount Allison UniversityCanadian Light Source
KeywordsImaging phantomMaterials scienceSynchrotronSynchrotron radiationArsenicX-ray fluorescenceRadiochemistryOpticsFluorescenceNuclear medicineChemistryPhysicsMedicine

Abstract

fetched live from OpenAlex

The differences and commonalities between x-ray fluorescence results obtained using synchrotron radiation and a portable x-ray fluorescence device were examined using arsenic in soft tissue phantoms and lead in bone phantoms. A monochromatic beam energy of 15.8 keV was used with the synchrotron, while the portable device employed a rhodium anode x-ray tube operated at 40 kV. Bone phantoms, dosed with varying quantities of lead, were made of Plaster of Paris and placed underneath skin phantoms of either 3.1 mm or 3.9 mm thickness. These skin phantoms were constructed from polyester resin, and dosed with varying amounts of arsenic. Using an irradiation time of 120 s, arsenic Kα and Kβ, and lead Lα and Lβ characteristic x-ray peaks were analysed. This information was used to calculate calibration line slopes and minimum detection limits for each data set. As expected, minimum detection limits were much lower at the synchrotron for detecting arsenic and lead. Both approaches produced lower detection limits for arsenic in soft tissue than for lead in bone when simultaneous detection was attempted. Although arsenic Kα and lead Lα emissions share similar energies, it was possible to detect both elements in isolation by using the arsenic Kβ and lead Lβ characteristic x-rays. Greater thickness of soft tissue phantom reduced the ability to detect the underlying lead. Experiments with synchrotron radiation could help guide future efforts toward optimizing a portable x-ray fluorescence in vivo measurement device.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.679
Threshold uncertainty score0.479

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.037
GPT teacher head0.258
Teacher spread0.221 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2017
Admission routes2
Has abstractyes

Explore more

Same venuePhysiological MeasurementSame topicAdvanced X-ray and CT ImagingFrench-language works237,207