Bedside Glucose Monitoring—Is it Safe? A New, Regulatory-Compliant Risk Assessment Evaluation Protocol in Critically Ill Patient Care Settings*
Bibliographic record
Abstract
OBJECTIVES: New data have emerged from ambulatory and acute care settings about adverse patient events, including death, attributable to erroneous blood glucose meter measurements and leading to questions over their use in critically ill patients. The U.S. Food and Drug Administration published new, more stringent guidelines for glucose meter manufacturers to evaluate the performance of blood glucose meters in critically ill patient settings. The primary objective of this international, multicenter, multidisciplinary clinical study was to develop and apply a rigorous clinical accuracy assessment algorithm, using four distinct statistical tools, to evaluate the clinical accuracy of a blood glucose monitoring system in critically ill patients. DESIGN: Observational study. SETTING: Five international medical and surgical ICUs. PATIENTS: All patients admitted to critical care settings in the centers. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Glucose measurements were performed on 1,698 critically ill patients with 257 different clinical conditions and complex treatment regimens. The clinical accuracy assessment algorithm comprised four statistical tools to assess the performance of the study blood glucose monitoring system compared with laboratory reference methods traceable to a definitive standard. Based on POCT12-A3, the Clinical Laboratory Standards Institute standard for hospitals about hospital glucose meter procedures and performance, and Parkes error grid clinical accuracy performance criteria, no clinically significant differences were observed due to patient condition or therapy, with 96.1% and 99.3% glucose results meeting the respective criteria. Stratified sensitivity and specificity analysis (10 mg/dL glucose intervals, 50-150 mg/dL) demonstrated high sensitivity (mean = 95.2%, SD = ± 0.02) and specificity (mean = 95. 8%, SD = ± 0.03). Monte Carlo simulation modeling of the study blood glucose monitoring system showed low probability of category 2 and category 3 insulin dosing error, category 2 = 2.3% (41/1,815) and category 3 = 1.8% (32/1,815), respectively. Patient trend analysis demonstrated 99.1% (223/225) concordance in characterizing hypoglycemic patients. CONCLUSIONS: The multicomponent, clinical accuracy assessment algorithm demonstrated that the blood glucose monitoring system was acceptable for use in critically ill patient settings when compared to the central laboratory reference method. This clinical accuracy assessment algorithm is an effective tool for comprehensively assessing the validity of whole blood glucose measurement in critically ill patient care settings.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.016 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.001 | 0.001 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".