MétaCan
Menu
Back to cohort
Record W2592706706

Cervical Total Level Arthroplasty System With PEEK All-Polymer Articulations

2011· dissertation· en· W2592706706 on OpenAlexfundno aff
Gordon Daniel George Langohr

Bibliographic record

VenueUWSpace (University of Waterloo) · 2011
Typedissertation
Languageen
FieldMedicine
TopicCervical and Thoracic Myelopathy
Canadian institutionsnot available
FundersNatural Sciences and Engineering Research Council of CanadaGovernment of Ontario
KeywordsPeekTotal hip arthroplastyArthroplastyMedicinePhysical therapySurgeryMaterials sciencePolymerComposite material
DOInot available

Abstract

fetched live from OpenAlex

The cervical spine must provide structural support for the head, allow large range of motion and protect both the spinal cord and branching nerves. There are two types of spinal joints: the intervertebral discs which are flexible connections and the facets, which are articulating synovial joints. Both types degenerate with age. Current surgical treatments include spinal fusion and articulating disc replacement implants. If both disc and facet joints are degenerated, fusion is the only option. In spinal fusion, the disc is removed and the adjacent vertebrae are fused which causes abnormally high stress levels in adjacent discs. In disc replacement, an articulating device is inserted to restore intervertebral motion and mimic healthy spinal kinematics. Disc arthroplasty does not significantly increase adjacent level stress but the lack of rotational constraint causes increased facet contact pressures. Thus, there is a need for a cervical total level arthroplasty system (CTLAS) that has a disc implant specifically designed to preserve the facet joints and implants for facet arthroplasty that can act independently or in-unison with the disc replacement. \n \nThe conceptual design of a CTLAS implant system was proposed that would replace the disc and the facet joints. To facilitate medical imaging, PEEK (polyetheretherkeytone) was selected as the structural and bearing material. In the present thesis, multi-station pin-on-plate wear testing was initiated for pairs of unfilled (OPT) and carbon-fiber-reinforced (CFR) PEEK. Wear is important in arthroplasty implant design because wear particles can cause osteolysis leading to loosening. A variety of experiments were performed to investigate the effects of load, contact geometry and lubricant composition on wear. CFR PEEK was found to have much lower and more predictable wear than OPT PEEK in the present experiments. The wear of OPT PEEK pairs showed sensitivity to lubricant protein concentration. The coefficient of friction during testing was found to be quite high (up to 0.5), which might have clinical implications. Also, some subsurface fatigue was found, exposing carbon fibers of CFR PEEK. This remains a concern for its long-term application. Further wear testing is recommended using actual implants in a spine wear simulator.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.008
Threshold uncertainty score0.028

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0080.004

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.216
Teacher spread0.195 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueUWSpace (University of Waterloo)Same topicCervical and Thoracic MyelopathyFrench-language works237,207