MétaCan
Menu
Back to cohort
Record W2593674278 · doi:10.1002/mrm.26622

Parallel radiofrequency transmission at 3 tesla to improve safety in bilateral implanted wires in a heterogeneous model

2017· article· en· W2593674278 on OpenAlexaff
Clare E. McElcheran, Benson P. Yang, Kevan Anderson, Laleh Golestanirad, Simon J. Graham

Bibliographic record

VenueMagnetic Resonance in Medicine · 2017
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsUniversity of TorontoSunnybrook Health Science Centre
Fundersnot available
KeywordsSpecific absorption rateImaging phantomMagnetic resonance imagingRadiofrequency coilElectromagnetic coilMaterials scienceElectrical conductorTransmission (telecommunications)Radio frequencyImage qualityBiomedical engineeringChannel (broadcasting)Nuclear medicineComputer sciencePhysicsRadiologyTelecommunicationsMedicineComposite material

Abstract

fetched live from OpenAlex

PURPOSE: Elongated implanted conductors can interact with the radiofrequency (RF) transmission field during MRI, posing safety concerns of excessive heating in patients with deep brain stimulators. A technique using parallel RF transmission (pTx) is evaluated on an anthropomorphic heterogeneous model with bilateral and unilateral curved wires. METHODS: Amplitude and phase were optimized by simulation to minimize heating surrounding the implanted wires and to minimize B1+ inhomogeneity for four-channel and eight-channel pTx in a heterogeneous model. MRI experiments were conducted in an equivalent test phantom created from a common digital mesh file. RESULTS: In four-channel pTx, maximum local specific absorption rate (SAR) was reduced in both unilateral and bilateral wires by 47% and 59%, respectively, but with compromised B1+ homogeneity. Optimized eight-channel pTx substantially reduced local SAR compared with birdcage coil RF excitation in both unilateral and bilateral wires (reduction of maximum local SAR of 79% and 87%, respectively). B1+ inhomogeneity was limited to 17% and 26%, respectively. Experimental validation with four-channel pTx showed 80% and 92% temperature reduction at the tips of wire 1 and wire 2, respectively. CONCLUSION: This pTx approach yields promising reductions in local SAR at the tips of unilateral and bilateral implanted wires while maintaining image quality in simulation and experiment. Magn Reson Med 78:2408-2415, 2017. © 2017 International Society for Magnetic Resonance in Medicine.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.326
Teacher spread0.304 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations68
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207