MétaCan
Menu
Back to cohort
Record W2595659267 · doi:10.1111/ggr.12169

Electron Probe Microanalysis of Bromine in Minerals and Glasses with Correction for Spectral Interference from Aluminium, and Comparison with Microbeam Synchrotron X‐Ray Fluorescence Spectrometry

2017· article· en· W2595659267 on OpenAlex
Chao Zhang, Jinru Lin, Yuanming Pan, Renfei Feng, Renat Almeev, François Holtz

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueGeostandards and Geoanalytical Research · 2017
Typearticle
Languageen
FieldPhysics and Astronomy
TopicX-ray Spectroscopy and Fluorescence Analysis
Canadian institutionsCanadian Light Source (Canada)University of Saskatchewan
FundersLeibniz-GemeinschaftGottfried Wilhelm Leibniz Universität HannoverDeutsche ForschungsgemeinschaftUniversity of Saskatchewan
KeywordsAnalytical Chemistry (journal)Electron microprobeMicrobeamMicroanalysisSynchrotronMass spectrometryX-ray fluorescenceChemistryDetection limitMicroprobeMineralogyFluorescenceOpticsChromatographyPhysics

Abstract

fetched live from OpenAlex

The strong spectral interference between Br‐ and Al‐induced X‐ray lines hampers the utilisation of electron probe microanalysis ( EPMA ) for measuring Br mass fractions in Al‐bearing minerals and glasses. Through measuring Br‐free Al‐bearing materials, we established an EPMA method to quantify the overlap from Al K α on Br L β, which can be expressed as a linear function of the Al 2 O 3 content. The count rate of the Br L β peak signal was enhanced by high beam currents and long measurement times. Application of this EPMA method to Al‐ and Br‐bearing materials, such as sodalite and scapolite, and to five experimental glasses yielded Br mass fractions (in the range of 250–4000 μg g −1 ) that are consistent with those measured by microbeam synchrotron X‐ray fluorescence (μ‐ SXRF ) spectrometry. The EPMA method has an estimated detection limit of ~ 100–300 μg g −1 . We propose that this method is useful for measuring Br mass fractions (hundreds to thousands of μg g −1 ) in Al‐bearing minerals and glasses, including those produced in Br‐doped experiments. In addition, the natural marialitic scapolite ( ON 70) from Mpwapwa (Tanzania) containing homogeneously distributed high mass fractions of Br (2058 ± 56 μg g −1 ) and Cl (1.98 ± 0.03% m/m ) is an ideal reference material for future in situ analyses.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.295
Threshold uncertainty score0.869

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.348
Teacher spread0.327 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it