MétaCan
Menu
Back to cohort
Record W2604821632 · doi:10.1373/jalm.2016.022848

Validation of a Capillary Electrophoresis Assay for Monitoring Iodine Nutrition in Populations for Prevention of Iodine Deficiency: An Interlaboratory Method Comparison

2017· article· en· W2604821632 on OpenAlexaff
Adriana Nori de Macedo, Joseph Macri, Patricia L Hudecki, Michelle Saoi, Matthew McQueen, Philip Britz‐McKibbin

Bibliographic record

VenueThe Journal of Applied Laboratory Medicine · 2017
Typearticle
Languageen
FieldMedicine
TopicThyroid Disorders and Treatments
Canadian institutionsHamilton Regional Laboratory Medicine ProgramMcMaster University
FundersCenters for Disease Control and Prevention
KeywordsIodideIodineCapillary electrophoresisChemistryDetection limitChromatographyInductively coupled plasma mass spectrometryPopulationMatrix (chemical analysis)UrineAnalytical Chemistry (journal)Mass spectrometryMedicineInorganic chemistryBiochemistry

Abstract

fetched live from OpenAlex

BACKGROUND: A capillary electrophoresis (CE) assay was recently introduced as a new method for monitoring iodine nutrition in large-scale epidemiological studies. However, further tests revealed unanticipated matrix-dependent interferences when analyzing submicromolar levels of iodide in human urine as the predominate ionic form of dietary iodine. Herein, we describe a rigorous validation study that was used to identify sources of bias and establish modifications to the original CE method to improve method accuracy. METHODS: An interlaboratory method comparison using CE with UV detection and inductively coupled plasma-mass spectrometry (ICP-MS) was performed to quantify urinary iodide concentrations (n = 71) independently at McMaster University and Hamilton General Hospital, as well as the CDC as part of their quality assurance program. A positive bias in the original CE method was indicated, and buffer conditions were subsequently optimized to overcome matrix interferences for reliable iodine status determination. RESULTS: Positive bias in CE was attributed to variable concentrations of sulfate, a major urinary anion interference with similar mobility to iodide under the conditions originally reported. By increasing the concentration of α-cyclodextrin in the background electrolyte, the CE method was able to tolerate urinary sulfate over its normal physiological range without loss in signal response for iodide. The optimized CE assay generated results that were consistent with ICP-MS using 2 different internal standards (187Re and 130Te) with a median bias under 10%. CONCLUSIONS: CE offers a simple, selective, and cost-effective separation platform for surveillance of the iodine status of a population requiring only small volumes (<10 μL) of biobanked urine specimens, which is comparable to previously validated screening methods currently used in global health initiatives for prevention of iodine deficiency disorders.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.028
metaresearch head score (Gemma)0.032
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.028
Threshold uncertainty score0.147

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0280.032
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0010.002
Scholarly communication0.0010.000
Open science0.0020.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.058
GPT teacher head0.395
Teacher spread0.337 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueThe Journal of Applied Laboratory MedicineSame topicThyroid Disorders and TreatmentsFrench-language works237,207