MétaCan
Menu
← Back to cohort
Record W2604987617 · doi:10.1139/cjc-2016-0558

Highly sensitive determination of copper (II) ions using fluorescence and chemiluminescence emissions of modified CdS quantum dots after it’s preconcentration by dispersive liquid–liquid microextraction

2017· article· en· W2604987617 on OpenAlexvenueno aff
Zohreh Saeedi, Ali Lotfi, Javad Hassanzadeh, Nafiseh Bagheri

Bibliographic record

VenueCanadian Journal of Chemistry · 2017
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicAdvanced biosensing and bioanalysis techniques
Canadian institutionsnot available
Fundersnot available
KeywordsChemistryCopperChemiluminescenceDetection limitIonic liquidFluorescenceIonAnalytical Chemistry (journal)Potassium permanganateMetal ions in aqueous solutionQuantum yieldQuenching (fluorescence)Aqueous solutionSelectivityChromatographyInorganic chemistryPhysical chemistry

Abstract

fetched live from OpenAlex

Two highly sensitive and selective methods based on fluorescence (FL) and chemiluminescence (CL) emissions of 8-mercaptoquinoline-capped CdS quantum dots (MCQ-CdS QDs) were described for the determination of copper (II) after it’s preconcentration. High fluorescent CdS QDs, synthesized in an aqueous medium, generated a relatively intense CL emission in the presence of potassium permanganate as an oxidant. Furthermore, low quantities of copper (II) ions showed a remarkable quenching effect on both of the CL and FL emissions of MCQ-CdS QDs. Based on this effect, two selective and simple methods were established for Cu2+, and the detection limits of 0.28 and 0.026 ng mL−1 were obtained for the FL and CL methods, respectively. Also, due to the high propensity of MCQ to Cu2+, good selectivity was obtained and no sensible interfering effects from other metal ions were observed. To more sensitize the developed method, an efficient preconcentration process was designed based on the high-yield ultrasound-assisted temperature-controlled ionic liquid dispersive liquid–liquid microextraction (UA-TIL-DLLME) method. Under the optimum conditions, the extracted Cu2+ showed a suppressing effect on the FL and CL emissions of CdS QDs proportional to its initial concentration over the ranges of 0.008–1.4 and 0.001–1.4 ng mL−1, respectively. The limits of detection of 3.7 and 0.37 pg mL−1, respectively, were also achieved. The established methods showed great features and were satisfactorily applied to the monitoring of ultratrace Cu2+ in some different environmental samples.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.262
Teacher spread0.251 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueCanadian Journal of Chemistry→Same topicAdvanced biosensing and bioanalysis techniques→French-language works237,207→