MétaCan
Menu
Back to cohort
Record W2607374045 · doi:10.1002/ccd.27040

Feasibility, safety, and efficacy of transcatheter aortic valve replacement without balloon predilation: A systematic review and meta‐analysis

2017· review· en· W2607374045 on OpenAlexaff
Vincent Auffret, Ander Regueiro, Francisco Campelo‐Parada, María Del Trigo, Olivier Chiche, Chekrallah Chamandi, Rishi Puri, Josep Rodés‐Cabau

Bibliographic record

VenueCatheterization and Cardiovascular Interventions · 2017
Typereview
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsUniversité Laval
Fundersnot available
KeywordsMedicineValve replacementConfidence intervalRelative riskMeta-analysisCardiologyBalloonInternal medicineClinical endpointSurgeryRandomized controlled trialStenosis

Abstract

fetched live from OpenAlex

OBJECTIVES: To evaluate the feasibility, safety, and efficacy of direct transcatheter aortic valve replacement (TAVR), that is, TAVR without balloon predilation (BPD), by performing a systematic review and meta-analysis of available evidence. BACKGROUND: Avoiding BPD during TAVR was shown to be feasible in previous studies but the risks and benefits of this technique are unknown owing to the limited number of patients included in these studies. METHODS: We performed a systematic search for studies comparing direct TAVR vs TAVR performed with BPD. Crude risk ratios (RRs) or mean differences and 95% confidence intervals (CI) for each endpoint were calculated using random effects models. RESULTS: Twenty studies including 3586 patients (1606 undergoing direct TAVR) were selected for the analysis. Mean device success with direct TAVR was 88% with <5% of bail-out techniques. There were no differences between direct and BPD-TAVR in short-term (in-hospital or 30-day) mortality (RR: 1.06; 95% CI: 0.78-1.43) or cerebrovascular events (RR: 0.92; 95% CI: 0.58-1.46). Direct TAVR associated with reduced moderate or severe paravalvular leak post-TAVR (RR: 0.59; 95% CI: 0.36-0.98) but not with a reduced risk of permanent pacemaker implantation (RR: 0.85, 95% CI: 0.71-1.02). A slight increase in postdilation was observed in direct transfemoral-TAVR recipients (RR: 1.2; 95% CI: 1.00-1.44). CONCLUSION: Direct TAVR is feasible and safe. However, given the unadjusted nature of our results, uncertainties remain regarding the independent effect of direct TAVR on outcomes post-TAVR. Randomized studies are warranted to determine the potential benefits of direct TAVR. © 2017 Wiley Periodicals, Inc.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.011
metaresearch head score (Gemma)0.028
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.017
Threshold uncertainty score0.060

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0110.028
Meta-epidemiology (narrow)0.0020.002
Meta-epidemiology (broad)0.0170.037
Bibliometrics0.0050.006
Science and technology studies0.0010.001
Scholarly communication0.0030.001
Open science0.0020.001
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.109
GPT teacher head0.417
Teacher spread0.309 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations43
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueCatheterization and Cardiovascular InterventionsSame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207