MétaCan
Menu
Back to cohort
Record W2608723843 · doi:10.1002/mp.12307

Validation of biomechanical deformable image registration in the abdomen, thorax, and pelvis in a commercial radiotherapy treatment planning system

2017· article· en· W2608723843 on OpenAlexafffund
Michael Velec, Joanne Moseley, Stina Svensson, Björn Hårdemark, David A. Jaffray, Kristy K. Brock

Bibliographic record

VenueMedical Physics · 2017
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of TorontoUniversity Health NetworkPrincess Margaret Cancer Centre
FundersNational Cancer InstituteCanadian Institutes of Health ResearchNational Institutes of Health
KeywordsImage registrationPelvisThorax (insect anatomy)AbdomenRadiation therapyRadiation treatment planningMedical imagingMedicineRadiologyMedical physicsNuclear medicineComputer visionComputer scienceImage (mathematics)Anatomy

Abstract

fetched live from OpenAlex

PURPOSE: The accuracy of deformable image registration tools can vary widely between imaging modalities and specific implementations of the same algorithms. A biomechanical model-based algorithm initially developed in-house at an academic institution was translated into a commercial radiotherapy treatment planning system and validated for multiple imaging modalities and anatomic sites. METHODS: Biomechanical deformable registration (Morfeus) is a geometry-driven algorithm based on the finite element method. Boundary conditions are derived from the model-based segmentation of controlling structures in each image which establishes a point-to-point surface correspondence. For each controlling structure, material properties and fixed or sliding interfaces are assigned. The displacements of internal volumes for controlling structures and other structures implicitly deformed are solved with finite element analysis. Registration was performed for 74 patients with images (mean vector resolution) of thoracic and abdominal 4DCT (2.8 mm) and MR (5.3 mm), liver CT-MR (4.5 mm), and prostate MR (2.6 mm). Accuracy was quantified between deformed and actual target images using distance-to-agreement (DTA) for structure surfaces and the target registration error (TRE) for internal point landmarks. RESULTS: The results of the commercial implementation were as follows. The mean DTA was ≤ 1.0 mm for controlling structures and 1.0-3.5 mm for implicitly deformed structures on average. TRE ranged from 2.0 mm on prostate MR to 5.1 mm on lung MR on average, within 0.1 mm or lower than the image voxel sizes. Accuracy was not overly sensitive to changes in the material properties or variability in structure segmentations, as changing these inputs affected DTA and TRE by ≤ 0.8 mm. Maximum DTA > 5 mm occurred for 88% of the structures evaluated although these were within the inherent segmentation uncertainty for 82% of structures. Differences in accuracy between the commercial and in-house research implementations were ≤ 0.5 mm for mean DTA and ≤ 0.7 mm for mean TRE. CONCLUSIONS: Accuracy of biomechanical deformable registration evaluated on a large cohort of images in the thorax, abdomen and prostate was similar to the image voxel resolution on average across multiple modalities. Validation of this treatment planning system implementation supports biomechanical deformable registration as a versatile clinical tool to enable accurate target delineation at planning and treatment adaptation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.013
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.027

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0050.013
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.338
Teacher spread0.314 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations61
Published2017
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207