MétaCan
Menu
Back to cohort
Record W2612686147 · doi:10.5383/swes.8.01.005

A Novel Low-Energy Ventilative Cooling System for Sustainable Built Environment

2016· article· en· W2612686147 on OpenAlex
Hassam Nasarullah Chaudhry

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

venuePublished in a venue whose home country is Canada.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueInternational Journal of Sustainable Water and Environmental Systems · 2016
Typearticle
Languageen
FieldEnvironmental Science
TopicWind and Air Flow Studies
Canadian institutionsnot available
Fundersnot available
KeywordsComputational fluid dynamicsCooling towerWater coolingReynolds-averaged Navier–Stokes equationsMarine engineeringWork (physics)RefrigerantEnvironmental sciencePassive coolingRoofInletWind speedMechanical engineeringHeat transferMeteorologyMechanicsEngineeringAerospace engineeringStructural engineeringPhysics

Abstract

fetched live from OpenAlex

A numerical investigation into determining the thermal and ventilation capability of wind towers integrated with the heat pipe technology was carried out in this work. The water-charged copper heat pipes were systematically arranged in a horizontal orientation and integrated inside a modern roof-mounted wind tower. Water was used as the working fluid instead of synthetic refrigerants in order to make the system carbon-neutral alongside maintaining the indoor air quality of the built environment. The three-dimensional Reynolds-Averaged Navier-Stokes (RANS) equations along with the momentum, continuity and energy equations were solved using the commercial Computational Fluid Dynamics (CFD) ANSYS code for velocity and pressure field simulations. Using the inlet wind speeds ranging from 1m/s to 5m/s, the results of the study showed that the proposed cooling system was capable of meeting the regulatory fresh air intake requirements per occupant of 10L/s. In addition, the findings determined that a passive cooling capacity of up to 11K was achievable when the system was subjected to inlet temperatures of 310K or 37°C. The work characterised the sustainable operation of wind tower in delivering energy-free ventilative cooling in regions encompassing hot and dry climatic conditions. The technology presented in this work is currently under an Intellectual Property (IP) protection (GB1321709.6).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.766
Threshold uncertainty score0.572

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.195
Teacher spread0.189 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it