MétaCan
Menu
Back to cohort
Record W2612686147 · doi:10.5383/swes.8.01.005

A Novel Low-Energy Ventilative Cooling System for Sustainable Built Environment

2016· article· en· W2612686147 on OpenAlexvenueno aff
Hassam Nasarullah Chaudhry

Bibliographic record

VenueInternational Journal of Sustainable Water and Environmental Systems · 2016
Typearticle
Languageen
FieldEnvironmental Science
TopicWind and Air Flow Studies
Canadian institutionsnot available
Fundersnot available
KeywordsComputational fluid dynamicsCooling towerWater coolingReynolds-averaged Navier–Stokes equationsMarine engineeringWork (physics)RefrigerantEnvironmental sciencePassive coolingRoofInletWind speedMechanical engineeringHeat transferMeteorologyMechanicsEngineeringAerospace engineeringStructural engineeringPhysics

Abstract

fetched live from OpenAlex

A numerical investigation into determining the thermal and ventilation capability of wind towers integrated with the heat pipe technology was carried out in this work. The water-charged copper heat pipes were systematically arranged in a horizontal orientation and integrated inside a modern roof-mounted wind tower. Water was used as the working fluid instead of synthetic refrigerants in order to make the system carbon-neutral alongside maintaining the indoor air quality of the built environment. The three-dimensional Reynolds-Averaged Navier-Stokes (RANS) equations along with the momentum, continuity and energy equations were solved using the commercial Computational Fluid Dynamics (CFD) ANSYS code for velocity and pressure field simulations. Using the inlet wind speeds ranging from 1m/s to 5m/s, the results of the study showed that the proposed cooling system was capable of meeting the regulatory fresh air intake requirements per occupant of 10L/s. In addition, the findings determined that a passive cooling capacity of up to 11K was achievable when the system was subjected to inlet temperatures of 310K or 37°C. The work characterised the sustainable operation of wind tower in delivering energy-free ventilative cooling in regions encompassing hot and dry climatic conditions. The technology presented in this work is currently under an Intellectual Property (IP) protection (GB1321709.6).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.195
Teacher spread0.189 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueInternational Journal of Sustainable Water and Environmental SystemsSame topicWind and Air Flow StudiesFrench-language works237,207