Flexible 19-Gauge Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration Needle: First Experience
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
BACKGROUND: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a well-established first-line invasive modality for mediastinal lymph node staging in lung cancer patients and in the diagnostic workup of patients with mediastinal adenopathy. With the current 21- and 22-gauge (G) EBUS-TBNA needles, the procedure can be limited by the degree of flexibility in the needle and the size of the lumen in tissue acquisition. OBJECTIVE: We report our initial experience with a first-generation flexible 19-G EBUS-TBNA (Flex 19G; Olympus Respiratory America, Redmond, WA, USA) needle with regards to efficacy and safety. METHODS: The Flex 19G EBUS-TBNA needle was used in 47 selected patients with enlarged hilar and/or mediastinal lymphadenopathy at 3 centers. The standard Olympus EBUS scope with a 2.2-mm working channel was used in all cases. RESULTS: The diagnostic yield of the Flex 19G needle according to clinical cytopathology reports was 89% (42/47). The diagnosis and their respective diagnostic yield with the Flex 19G EBUS-TBNA needle were malignancy 24/27 (89%), sarcoidosis 13/14 (93%), and reactive lymph node hyperplasia 5/6 (83%). The mean short axis of the sampled lymph nodes was 19 ± 9 mm. No complications occurred except for 1 instance of moderate bleeding, which did not require intervention beyond suctioning and subsequently resolved. All 13 patients diagnosed with adenocarcinoma by the 19-G needle had sufficient tissue for genetic testing. CONCLUSION: EBUS-TBNA using the first-generation Flex 19G needle is feasible and safe with promising diagnostic yield while providing a greater degree of flexion with the Olympus EBUS scope. Additional clinical evaluations are warranted.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.001 | 0.000 |
| Scholarly communication | 0.000 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it