MétaCan
Menu
Back to cohort
Record W2673071856 · doi:10.1002/mp.12421

Sensitive volume effects on Monte Carlo calculated ion chamber response in magnetic fields

2017· article· en· W2673071856 on OpenAlexafffund
Victor Malkov, D. W. O. Rogers

Bibliographic record

VenueMedical Physics · 2017
Typearticle
Languageen
FieldMedicine
TopicRadiation Therapy and Dosimetry
Canadian institutionsCarleton University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsMonte Carlo methodIonization chamberComputational physicsMagnetic fieldVolume (thermodynamics)PhysicsDosimetryNuclear medicineIonNuclear magnetic resonanceNuclear physicsMaterials scienceMedicineIonizationMathematicsStatistics

Abstract

fetched live from OpenAlex

PURPOSE: The development of magnetic resonance-guided radiation therapy (MRgRT) necessitates accurate Monte Carlo (MC) models of ion chambers for computing ion chamber corrections to compensate for the presence of the magnetic field. This study evaluates the sensitivity of the ion chamber dose response in a magnetic field on the collection volume used in the MC simulation. METHODS: The EGSnrc system's egs_chamber application is used with a recently developed and validated magnetic field transport code. The calculated dose to the sensitive volume of the chamber per unit incident photon fluence, normalized to that at 0 T, is evaluated as a function of magnetic field for the PTW 30013, PTW 31006, PTW 31010, Exradin A12S, and Exradin A1SL chambers. The sensitive region is varied by excluding the volume corresponding to either 0, 0.5, or 1 mm of distance away from the stem. The photon field, magnetic field, and ion chamber are all oriented perpendicular to each other as in the majority of published experimental works. RESULTS: A1SL chamber. Larger volume chambers showed smaller, but still non-negligible, variations. Simulations of the A1SL chamber with a 7 MV photon source, corresponding to the Elekta MR-linac machine, demonstrate that the effect is slightly reduced but still persists with a maximum deviation of 1.97 ± 0.08% for the 1 mm reduction. CONCLUSIONS: Usually, the geometric sensitive volume of the ion chamber is used in MC calculation as a substitute for the potentially unknown, smaller, true collection volume (governed by the complex electric field distribution inside the chamber). The calculations in this study demonstrate that even a small variation in simulated volume can lead to fairly large variations in the MC calculated ion chamber response in a magnetic field. This is an important effect that must be addressed to ensure proper calibration of MRgRT machines using MC ion chamber correction factors. This effect may play a role, even where there is no magnetic field, in small-field dosimetry when volume averaging effect are important.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.773
Threshold uncertainty score0.417

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.282
Teacher spread0.272 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations41
Published2017
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicRadiation Therapy and DosimetryFrench-language works237,207