Mechanical insufflation-exsufflation: Practice patterns among respiratory therapists in Ontario.

2015· article· en· W270828900 on OpenAlexaffabout
Shelley Prevost, Dina Brooks, Phillip Bwititi

Bibliographic record

VenuePubMed · 2015
Typearticle
Languageen
FieldMedicine
TopicRespiratory Support and Mechanisms
Canadian institutionsUniversity of TorontoSt. Joseph's Care Group
Fundersnot available
KeywordsMedicineRespiratory therapistNeuromuscular diseaseRespiratory careEmergency medicineIntensive care medicineDiseaseInternal medicine
DOInot available

Abstract

fetched live from OpenAlex

BACKGROUND: The mechanical insufflator-exsufflator (MIE) is effective in assisting cough and in helping to avoid unplanned hospitalizations, tracheostomy and long-term ventilation in patients with neuromuscular disease or spinal cord injury. Despite this, the availability and usage of the device in Canada is unknown. OBJECTIVE: To investigate practice patterns and availability of the MIE in Ontario hospitals. METHODS: A cross-sectional, self-administered mail survey was sent to a random sample of 400 respiratory therapists practicing in 96 Ontario hospitals. RESULTS: A total of 114 (28%) completed surveys were returned from 62 (65%) hospitals. Twenty (32%) hospitals had a MIE. The respiratory therapist was the predominant health care provider using the MIE. The device was most commonly used in the intensive care unit, and medical/surgical units in patients with neuromuscular diseases or spinal cord injuries. Optimal pressure spans of 35 cmH2O to 40 cmH2O were used by 54% of respondents. Fourteen of the 20 hospitals with an MIE had policies or guidelines in place, and four of these hospitals had established staff competencies. Measurements of peak cough flow, maximal inspiratory/expiratory pressure and vital capacity were reported to be infrequently performed. CONCLUSIONS: The present study demonstrated that the MIE device is not widely available in Ontario hospitals and there are variations in how the devices are applied, possibly resulting in suboptimal therapy. A comprehensive educational program about MIE devices that incorporates best practices and a practical component is recommended for current providers as well as for inclusion in student curricula.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.193
Threshold uncertainty score0.388

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.000
Open science0.0000.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.081
GPT teacher head0.280
Teacher spread0.199 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2015
Admission routes2
Has abstractyes

Explore more

Same venuePubMedSame topicRespiratory Support and MechanismsFrench-language works237,207