MétaCan
Menu
Back to cohort
Record W2715913463 · doi:10.47339/ephj.2015.115

Contrasting the effectiveness of chloramines reduction in indoor swimming pools disinfected by ozone versus UV

2015· article· en· W2715913463 on OpenAlexvenueno aff
Iris Hiu-Shuen Chan, Environmental Health BCIT School of Health Sciences, Bobby Sidhu

Bibliographic record

VenueBCIT Environmental Public Health Journal · 2015
Typearticle
Languageen
FieldEnvironmental Science
TopicWater Treatment and Disinfection
Canadian institutionsnot available
Fundersnot available
KeywordsChloramineChlorineOzoneEnvironmental chemistryChemistryEnvironmental science

Abstract

fetched live from OpenAlex


 Objectives: Chloramines are disinfection by-products that are produced between chlorine and contaminants in the pool. Exposures to chloramines at high levels or for extended durations have been found to cause mucous membrane irritations and respiratory distress in humans. To reduce chloramines production, secondary treatment in the form of UV and ozone are used in newer indoor swimming pools. This study aimed to examine whether there is a difference between UV and ozone treatment in their effectiveness in reducing chloramines in indoor pools. Killarney leisure pool and whirlpool, which utilized ozone treatment, as well as Hillcrest leisure pool and whirlpool, which utilized UV treatment, were studied. Methods: Hach Pocket Colorimeter 2 Analysis System which used a DPD method of analysis was used to determine concentrations of free chlorine and total chlorines. Concentrations of chloramines were calculated by subtracting the concentration of free chlorine from total chlorine. Thirty pool water samples for each type of pool system were analyzed on random days in the afternoons of January and February, 2015. A two sample t-test was used to compare the chloramines concentrations of the whirlpools; while a Mann-Whitney U test was used to compare the chloramines concentrations of the leisure pools. Results: There was a statistically significant difference between the mean chloramines concentration of the UV-treated whirlpool and that of the ozone-treated whirlpool (p = 0.00854). However, there was not a statistically significant difference between the mean chloramines concentration between the UV treated leisure pool and that of the ozone treated leisure pool (p = 0.882048). Conclusions: It was determined that UV was more effective than ozone in reducing chloramines concentrations in indoor public whirlpools. Therefore, in order to choose a treatment that leads to the greatest reduction of health hazard posed to pool patrons, UV is preferred. Whirlpools that intend to adopt secondary treatment may consider UV.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.042
Threshold uncertainty score0.585

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.034
GPT teacher head0.263
Teacher spread0.229 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueBCIT Environmental Public Health JournalSame topicWater Treatment and DisinfectionFrench-language works237,207