MétaCan
Menu
Back to cohort
Record W2728554424 · doi:10.2967/jnumed.116.182899

Operational and Dosimetric Aspects of Pediatric PET/CT

2017· review· en· W2728554424 on OpenAlexfundno aff
Frederic H. Fahey, Alison Goodkind, Robert MacDougall, Leah Oberg, Sonja I. Ziniel, Richard Cappock, Michael J. Callahan, Neha Kwatra, S. Ted Treves, Stephan D. Voss

Bibliographic record

VenueJournal of Nuclear Medicine · 2017
Typereview
Languageen
FieldMedicine
TopicRadiation Dose and Imaging
Canadian institutionsnot available
FundersHospital for Sick ChildrenSeattle Children's Research InstituteChildren's National HospitalChildren's Hospital of PittsburghChildren's Hospital ColoradoTexas Children's HospitalChildren's Mercy HospitalCincinnati Children's Hospital Medical CenterBC Children's HospitalSociety of Nuclear Medicine and Molecular ImagingMassachusetts General HospitalChildren's Hospital of PhiladelphiaChildren's Hospital Los Angeles
KeywordsMedical physicsMedicinePET-CTImage qualityStandardizationDosimetryNuclear medicineRadiation doseRadiologyPositron emission tomographyComputer scienceComputer vision

Abstract

fetched live from OpenAlex

No consistent guidelines exist for the acquisition of a CT scan as part of pediatric PET/CT. Given that children may be more vulnerable to the effects of ionizing radiation, it is necessary to develop methods that provide diagnostic-quality imaging when needed, in the shortest time and with the lowest patient radiation exposure. This article describes the basics of CT dosimetry and PET/CT acquisition in children. We describe the variability in pediatric PET/CT techniques, based on a survey of 19 PET/CT pediatric institutions in North America. The results of the survey demonstrated that, although most institutions used automatic tube current modulation, there remained a large variation of practice, on the order of a factor of 2-3, across sites, pointing to the need for guidelines. We introduce the approach developed at our institution for using a multiseries PET/CT acquisition technique that combines diagnostic-quality CT in the essential portion of the field of view and a low-dose technique to image the remainder of the body. This approach leads to a reduction in radiation dose to the patient while combining the PET and the diagnostic CT into a single acquisition. The standardization of pediatric PET/CT provides an opportunity for a reduction in the radiation dose to these patients while maintaining an appropriate level of diagnostic image quality.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.938
Threshold uncertainty score0.576

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0020.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.094
GPT teacher head0.397
Teacher spread0.303 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations52
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Nuclear MedicineSame topicRadiation Dose and ImagingFrench-language works237,207