MétaCan
Menu
Back to cohort
Record W2730835714 · doi:10.14447/jnmes.v19i4.277

Trace Determination of Lead and Cadmium using Graphene/[Ru(NH3)6]3+/Nafion Modi-fied Glassy Carbon Electrodes

2017· article· en· W2730835714 on OpenAlexvenueno aff
Shirley Palisoc, Michelle Natividad, Diana Mae Mae Calde, Elias Rafael Rosopa

Bibliographic record

VenueJournal of New Materials for Electrochemical Systems · 2017
Typearticle
Languageen
FieldChemistry
TopicElectrochemical Analysis and Applications
Canadian institutionsnot available
Fundersnot available
KeywordsGrapheneNafionMaterials scienceCyclic voltammetryElectrodeDetection limitAnalytical Chemistry (journal)Glassy carbonAnodic stripping voltammetryInorganic chemistryElectrochemistryChemistryNanotechnologyChromatography

Abstract

fetched live from OpenAlex

Graphene/[Ru(NH3)6]3+/nafion modified glassy carbon electrodes were fabricated using the drop coating technique. The fab-ricated electrodes were characterized using scanning electron microscopy (SEM) and cyclic voltammetry (CV). Simultaneous detection of lead (Pb2+) and cadmium (Cd2+) was done via anodic stripping voltammetry (ASV). The effects of varying the amounts of graphene and [Ru(NH3)6]3+ on the transport and sensing properties of the modified electrodes were determined. SEM results showed that the deposited films were smooth and uniform. CV results showed that the peak currents increase monotonically with the amounts of graphene and [Ru(NH3)6]3+. ASV results showed that modification of the GCE with graphene, [Ru(NH3)6]3+ and Nafion greatly enhanced the electrode’s sensitivity in detecting Pb2+ and Cd2+. This can be attributed to the high surface area-to-volume ratio of graphene, the mediation of elec-tron transfer by [Ru(NH3)6]3+ and the antifouling and cationic exchange capabilities of Nafion. The highest peak current for both Pb2+ and Cd2+ were obtained from the electrode modified with 1.5 mg [Ru(NH3)6]3+ and 3.0 mg graphene. A linear relationship between the peak current and metal concentration was obtained in the range of 1.4 ppb to 20 ppb for both Pb2+ and Cd2+ with a detection limit of 1.4 ppb. The modified electrodes were successful in detecting Cd2+ in real water samples. ASV results were verified using atomic absorption spec-troscopy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.917

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.289
Teacher spread0.264 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueJournal of New Materials for Electrochemical SystemsSame topicElectrochemical Analysis and ApplicationsFrench-language works237,207