Performance analysis of the T‐DOC® air‐charged catheters: An alternate technology for urodynamics

2017· article· en· W2735856958 on OpenAlexaff
Bruna M. Couri, Stephanie Bitzos, Deepak Bhardwaj, Emily Lockhart, Andy Yue, Ing Goping

Bibliographic record

VenueNeurourology and Urodynamics · 2017
Typearticle
Languageen
FieldMedicine
TopicUrinary Bladder and Prostate Research
Canadian institutionsUniversity of Guelph
Fundersnot available
KeywordsMedicineLinearityHysteresisCatheterPressure measurementPressure sensorBiomedical engineeringAnesthesiaSurgeryElectrical engineeringMeteorology

Abstract

fetched live from OpenAlex

AIMS: Urodynamics (UDS) is widely used for the diagnosis of lower urinary tract dysfunction. Air-Charged catheters (ACC), one of the newer technologies for UDS pressure recording, has been adopted in growing numbers around the world for the past 15 years. Currently, there is a lack of published studies characterizing specific performance of the ACC. Since linearity, hysteresis, pressure drift, and frequency response are important components in characterizing accuracy for catheter-manometer systems; this study aimed to assess these four aspects in ACC. METHODS: A total of 180 T-DOC® ACC were used in three different laboratory settings to assess pressure linearity and hysteresis (15 dual-sensor vesical and urethral and 30 single-sensor abdominal), pressure drift over 2 h (115 single-sensor), and frequency response (20 single-sensor). Data are presented as mean ± standard deviation. RESULTS: ACC showed linearity of 0.99 ± 0.01, 0.99 ± 0.01, and 1.01 ± 0.01; and hysteresis of 0.57 ± 0.3%, 0.76 ± 0.48%, and 1 ± 0.89% for the abdominal, vesical, and urethral sensors, respectively. A pressure drift of 2.2 ± 1.4% at 1 h and 4.4 ± 2.5% at 2 h were observed when compared to baseline pressures. The catheters did not show any amplification factor during the sweep from 1 to 30 Hz, and recorded signals up to 5 Hz attenuating higher frequency signals. CONCLUSIONS: In this study the T-DOC® ACC showed a linear performance with minimal hysteresis associated with acceptable pressure drift, and adequate frequency response to capture clinically relevant pressures. The accurate results observed in this study suggest that these catheters are technically suitable to be used as a measuring instrument for UDS.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.016

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.005
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.320
Teacher spread0.299 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations17
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueNeurourology and UrodynamicsSame topicUrinary Bladder and Prostate ResearchFrench-language works237,207