MétaCan
Menu
Back to cohort
Record W2736178470 · doi:10.1161/circep.116.004874

Automated Quantification of Low-Amplitude Abnormal QRS Peaks From High-Resolution ECG Recordings Predicts Arrhythmic Events in Patients With Cardiomyopathy

2017· article· en· W2736178470 on OpenAlexaff
Moloy Das, Adrian Suszko, Sachin Nayyar, Karthik Viswanathan, Danna Spears, George Tomlinson, Arnold Pintér, Eugene Crystal, Rupin Dalvi, Sridhar Krishnan, Vijay S. Chauhan

Bibliographic record

VenueCirculation Arrhythmia and Electrophysiology · 2017
Typearticle
Languageen
FieldMedicine
TopicCardiac electrophysiology and arrhythmias
Canadian institutionsToronto Metropolitan UniversityUniversity Health NetworkSunnybrook Health Science CentreSt. Michael's Hospital
Fundersnot available
KeywordsMedicineCardiologyQRS complexInternal medicineEjection fractionCardiomyopathyHazard ratioSignal-averaged electrocardiogramElectrocardiographyHeart failureIschemic cardiomyopathyConfidence interval

Abstract

fetched live from OpenAlex

Background— Cardiomyopathy patients are at risk of sudden death, typically from scar-related abnormalities of electrical activation that promote ventricular tachyarrhythmias. Abnormal intra-QRS peaks may provide a measure of altered activation. We hypothesized that quantification of such QRS peaks (QRSp) in high-resolution ECGs would predict arrhythmic events in implantable cardioverter–defibrillator (ICD)–eligible cardiomyopathy patients. Methods and Results— Ninety-nine patients with ischemic or non-ischemic dilated cardiomyopathy undergoing prophylactic ICD implantation were prospectively enrolled (age 62±11 years, left ventricular ejection fraction 27±7%). High-resolution (1024 Hz) digital 12-lead ECGs were recorded during intrinsic rhythm. QRSp was quantified for each precordial lead as the total number of low-amplitude deflections that deviated from their respective naive QRS template. The primary end point of arrhythmic events was defined as appropriate ICD therapy or sustained ventricular tachyarrhythmias. After a median follow-up of 24 (15–43) months, 20 (20%) patients had arrhythmic events. Both QRSp and QRS duration were greater in those with arrhythmic events (both P <0.001) and this was consistent for QRSp for both cardiomyopathy types. In a multivariable Cox regression model that included age, left ventricular ejection fraction, QRS duration, and QRSp, only QRSp was an independent predictor of arrhythmic events (hazard ratio, 2.1; P <0.001). Receiver operating characteristic analysis revealed that a QRSp ≥2.25 identified arrhythmic events with greater sensitivity (100% versus 70%, P <0.05) and negative predictive value (100% versus 89%, P <0.05) than QRS duration ≥120 ms. Conclusions— QRSp measured from high-resolution digital 12-lead ECGs independently predicts ventricular tachyarrhythmias in ICD-eligible cardiomyopathy patients. This novel QRS morphology index has the potential to improve sudden death risk stratification and patient selection for prophylactic ICD therapy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.354
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.227
Teacher spread0.221 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueCirculation Arrhythmia and ElectrophysiologySame topicCardiac electrophysiology and arrhythmiasFrench-language works237,207