Record W2738263322 · doi:10.1177/0018720817720339

Grip Type Alters Maximal Pinch Forces in Syringe Use

2017· article· en· W2738263322 on OpenAlexafffund
Victoria MacDonald, Katherine E. Wilson, Michael Sonne, Peter J. Keir

Bibliographic record

VenueHuman Factors The Journal of the Human Factors and Ergonomics Society · 2017
Typearticle
Languageen
FieldMedicine
TopicMusculoskeletal pain and rehabilitation
Canadian institutionsMcMaster UniversityCanada Auto WorkersHolland Bloorview Kids Rehabilitation HospitalHamilton Health Sciences
FundersNatural Sciences and Engineering Research Council of CanadaUniversity of Waterloo
KeywordsSyringePinchIsometric exerciseHand strengthPhysical medicine and rehabilitationPlungerMedicinePhysical therapyBiomedical engineeringGrip strengthEngineeringMechanical engineering

Abstract

fetched live from OpenAlex

OBJECTIVE: The purpose of this study was to determine maximum forces during syringe use for different grips found in the field. BACKGROUND: Prolonged syringe use in chemotherapy drug delivery is associated with pain and injury in nurses and technicians. METHOD: Twenty healthy female hospital workers generated isometric maximum voluntary force using a 30 cc syringe with four pinch grips (chuck, chuck variation, thenar, two-handed). Both dominant and nondominant hands were used with the syringe plunger fixed in wide (8.3 cm) and narrow (2.5 cm) grip spans. Participants were encouraged to position the apparatus in the most comfortable position and exert a maximal effort for 5 seconds. RESULTS: Significant interaction effects were found: Grip Span × Pinch Type, Hand × Pinch Type, and Grip Span × Hand × Pinch Type ( p < .05). The results demonstrated that the thenar (103.6 ± 22.9 N) and two-handed (104.7 ± 17.1 N) pinches produced the highest forces. CONCLUSION: Thenar and two-handed pinch grips may be the preferred pinch type to lower the relative efforts required to use a syringe and may be one strategy to assist with reduction of musculoskeletal disorder risk associated with syringe use. APPLICATION: Determining maximal syringe press forces allows workers and ergonomists to develop better strategies for managing the cumulative loads during drug delivery and mixing.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.004
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.046
GPT teacher head0.298
Teacher spread0.252 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2017
Admission routes2
Has abstractyes

Explore more

Same venueHuman Factors The Journal of the Human Factors and Ergonomics SocietySame topicMusculoskeletal pain and rehabilitationFrench-language works237,207