MétaCan
Menu
Back to cohort
Record W2739604163 · doi:10.1111/iwj.12784

Evaluation of a muscle pump‐activating device for non‐healing venous leg ulcers

2017· article· en· W2739604163 on OpenAlexaffabout
Connie Harris, Rochelle Duong, Gwen Vanderheyden, Beth Byrnes, Renee Cattryse, Ava Orr, David Keast

Bibliographic record

VenueInternational Wound Journal · 2017
Typearticle
Languageen
FieldMedicine
TopicDiagnosis and Treatment of Venous Diseases
Canadian institutionsParkwood InstituteWestern UniversityCARE CanadaHome and Community Care Support Services
Fundersnot available
KeywordsMedicineWound healingPopulationSurgeryVenous leg ulcerWound careAnesthesiaPhysical therapy

Abstract

fetched live from OpenAlex

This evaluation involves an innovative muscle pump-activating device (geko™) as an adjunctive therapy with best practices for non-healing venous leg ulcers (VLUs). Stimulating the common peroneal nerve (at the fibular head), the geko™ device creates a response that acts as foot and calf muscle pumps, increasing venous, arterial and microcirculatory flow. The aim was to evaluate and determine if the geko™ is effective in this population and if it should be added to the medical supply formulary. In all, 12 patients with 18 recalcitrant VLUs (defined as less than 30% reduction in wound size in 30 days with best practices) in two community settings in Ontario consented to the evaluation and were treated with the geko™ for up to 20 weeks. A total of 44% of wounds healed, and 39% decreased in size. One patient non-adherent with the geko™ and best practices had deterioration in his or her wounds. With the patients as their own control, the mean weekly healing rate with the geko™ was 9·35% (±SD 0·10) compared to 0·06% (±SD 0·10) prior to baseline, which was statistically significant (P < 0·01). Three patients not in optimal therapy increased compression due to decreased pain, further enabling healing. This study was not a randomised investigation, although the patients acted as their own controls. A pragmatic evaluation reflects the reality of the community sector; in spite of best practices or evidence-based care, therapy is not uniformly applied, with some participants unable to tolerate or indeed comply with optimal compression therapy. Rash occurred under the devices in 7 of 12 (58%) patients. One patient stopped the device due to rash, while another had to take breaks from using the device. Subsequently, the manufacturer (FirstKind Ltd) has developed a new device and protocol specific to the requirements of wound therapy to minimise this response. This small case series demonstrated the highly significant effectiveness of the geko™ device in these hard-to-heal VLUs. Further evaluations to determine dose and patient selection criteria are underway.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.884
Threshold uncertainty score0.310

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.093
GPT teacher head0.407
Teacher spread0.315 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2017
Admission routes2
Has abstractyes

Explore more

Same venueInternational Wound JournalSame topicDiagnosis and Treatment of Venous DiseasesFrench-language works237,207