THE NATURAL HISTORY OF FULL-FIELD STIMULUS THRESHOLD DECLINE IN CHOROIDEREMIA
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
PURPOSE: To evaluate full-field sensitivity thresholds (FSTs) across a wide range of choroideremia (CHM) disease stages and to determine their applicability as functional endpoints for CHM clinical trials. METHODS: Thirty CHM subjects (60 eyes) and 50 healthy controls (50 eyes) underwent FST testing under dark-adapted conditions to determine rod- and cone-mediated FSTs. Central retinal structure and function were assessed using fundus autofluorescence and microperimetry. Correlation and regression analyses were performed to compare FST responses with the residual area of retinal pigment epithelium in the peri- and parafoveal regions, as well as the mean and highest macular microperimetry sensitivity. RESULTS: All patients with CHM had a baseline of 18 dB elevation in dark-adapted rod FSTs, including the least affected individuals. Further FST sensitivity loss was exponentially associated with decrease in the area of residual peri- and parafoveal retinal pigment epithelium, with precipitous loss of sensitivity noted for fundus autofluorescence areas less than 5 mm. Cone FSTs were comparable with controls, except for advanced stages of CHM. Full-field sensitivity threshold responses showed high correlation with both mean and highest macular microperimetry thresholds (P < 0.001). In some cases of absent macular fundus autofluorescence, the peripheral retina could contribute to detectable rod FST responses but with severely diminished cone-driven responses. CONCLUSION: Full-field sensitivity threshold testing demonstrated a baseline level of rod dysfunction in CHM present in all rod photoreceptors. Further decline in FST responses correlated strongly with the extent of central retina structural and functional loss. Full-field sensitivity threshold allowed quantification of residual rod function in peripheral islands of vision, which cannot be reliably achieved with other conventional tests. As such, the FST can serve as a complimentary tool to guide patient selection and expand the eligibility criteria for current and future CHM clinical trials.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it