MétaCan
Menu
Back to cohort
Record W2745253037 · doi:10.1167/iovs.17-22412

The Effect of Acutely Elevated Intraocular Pressure on the Functional and Blood Flow Responses of the Rat Retina to Flicker Stimulation

2017· article· en· W2745253037 on OpenAlexaff
Bingyao Tan, Benjamin MacLellan, Erik Mason, Kostadinka Bizheva

Bibliographic record

VenueInvestigative Ophthalmology & Visual Science · 2017
Typearticle
Languageen
FieldMedicine
TopicGlaucoma and retinal disorders
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsFlickerRetinaStimulationOphthalmologyBlood flowMedicineIntraocular pressureBlood pressureNeuroscienceInternal medicinePsychologyComputer science

Abstract

fetched live from OpenAlex

Purpose: To evaluate the effect of acutely elevated intraocular pressure (IOP) on the functional and blood flow responses of the rat retina to flicker stimulation. Methods: Brown Norway (n = 15) rats were dark-adapted before ketamine/xylazine anesthesia. IOP was raised acutely in one eye to ∼45 mm Hg with a vascular loop. In 11 rats, white light flicker stimulus (10 Hz, 2 seconds duration, 0.80 log scotopic cd·s/m2) was applied before and during IOP elevation, and 10 minutes after loop removal. Changes in the total retinal blood flow (TRBF) and retinal function induced by the visual stimulus were measured simultaneously with a combined optical coherence tomography (OCT) + electroretinography (ERG) system. Systemic blood pressure was measured in the remaining four rats frequently from 10 to 90 minutes post anesthesia injection. Results: The systemic blood pressure remained at 99 ± 4 mm Hg throughout the measurements (n = 4). Under normal IOP, the TRBF was 5.6 ± 1.9 μL/min, and the average retinal blood vessel size (BVS) in the vicinity of the optic nerve head (ONH) was 44.1 ± 4.5 μm. During IOP elevation, the TRBF was significantly lower (3.8 ± 1.2 μL/min, P < 0.01) and the BVS was significantly smaller (35.1 ± 2.6 μm, P < 0.01). Both TRBF and BVS returned to baseline within ∼10 minutes from removal of the vascular loop. The flicker-induced TRBF change measured under normal IOP (6.0 ± 3.3%) was reduced significantly to 0.1 ± 0.3% (P < 0.01) during IOP elevation, and recovered to 5.9 ± 1.7% within 10 minutes after loop removal. During IOP elevation, the magnitude of the ERG second harmonic component (SHC) decreased to 55% of its baseline value (P < 0.01) and remained significantly smaller than baseline (P < 0.01). Conclusions: Acute IOP elevation to 45 mm Hg caused suppression of the retinal functional and TRBF response to flicker stimulation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.325
Teacher spread0.299 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueInvestigative Ophthalmology & Visual ScienceSame topicGlaucoma and retinal disordersFrench-language works237,207