MétaCan
Menu
Back to cohort
Record W2745338341 · doi:10.1155/2017/4310314

Biomechanical Measurement Error Can Be Caused by Fujifilm Thickness: A Theoretical, Experimental, and Computational Analysis

2017· article· en· W2745338341 on OpenAlexaff
Ahmed Sarwar, Simli Srivastava, Chris Chu, Alan Machin, Emil H. Schemitsch, Habiba Bougherara, Zahra S. Bagheri, Radovan Zdero

Bibliographic record

VenueBioMed Research International · 2017
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsToronto Rehabilitation InstituteWestern UniversityVictoria HospitalToronto Metropolitan University
Fundersnot available
KeywordsCylinderMaterials scienceFinite element methodMathematicsPhysicsGeometryThermodynamics

Abstract

fetched live from OpenAlex

This is the first study to quantify the measurement error due to the physical thickness of Fujifilm for several material combinations relevant to orthopaedics. Theoretical and experimental analyses were conducted for cylinder-on-flat indentation over a series of forces (750 and 3000 N), cylinder diameters (0 to 80 mm), and material combinations (metal-on-metal, MOM; metal-on-polymer, MOP; metal-on-bone, MOB). For the scenario without Fujifilm, classic Hertzian theory predicted the true line-type contact width as WO={(8FDcyl)/(πLcyl)[(1-νcyl2)/Ecyl+(1-νflat2)/Eflat]}1/2 , where F is compressive force, Dcyl is cylinder diameter, Lcyl is cylinder length, νcyl and νflat are cylinder and flat Poisson’s ratios, and Ecyl and Eflat are cylinder and flat elastic moduli. For the scenario with Fujifilm, experimental measurements resulted in contact widths of WF=0.1778×F0.2273×D0.2936 for MOM tests, WF=0.0449×F0.4664×D0.4201 for MOP tests, and WF=0.1647×F0.2397×D0.3394 for MOB tests, where F is compressive force and D is cylinder diameter. Fujifilm thickness error ratio WF/WO showed a nonlinear decrease versus cylinder diameter, whilst error graphs shifted down as force increased. Computational finite element analysis for several test cases agreed with theoretical and experimental data, respectively, to within 3.3% and 1.4%. Despite its wide use, Fujifilm’s measurement errors must be kept in mind when employed in orthopaedic biomechanics research.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.022
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.022

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.022
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.002
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.122
GPT teacher head0.419
Teacher spread0.297 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueBioMed Research InternationalSame topicOrthopaedic implants and arthroplastyFrench-language works237,207