MétaCan
Menu
← Back to cohort
Record W2751630561 · doi:10.7759/cureus.1638

Targeting the Tumor: Assessing the Impact of Bladder Volume and Position on Accuracy of Radiation Delivery for Patients with Bladder Cancer

2017· article· en· W2751630561 on OpenAlexaff
Andrew Kochan, Ryan Rivest, Katie Galloway, Pascal Lambert, Aldrich Ong, Rashmi Koul, Shahida Ahmed, Bashir Bashir, Harvey Quon

Bibliographic record

VenueCureus · 2017
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsCancerCare ManitobaUniversity of Manitoba
Fundersnot available
KeywordsMedicineBladder cancerContext (archaeology)Radiation therapyNuclear medicineCone beam computed tomographyPopulationUrologyComputed tomographyRadiologyCancerInternal medicine

Abstract

fetched live from OpenAlex

Context Daily variations in bladder size and position can negatively impact the ability to accurately deliver radiation. Aims We attempted to quantify how bladder volumes and positions change over the course of radiotherapy for muscle invasive bladder cancer and the planning target volume (PTV) margins required to account for such changes. Methods and material Cone-beam computed tomography (CT) images of 28 patients during their first, second, and third fractions and weekly thereafter were acquired. Bladders were contoured and the volume, centre of mass, and the maximal positions were recorded and compared to the planning CT scan. Statistical analysis Bladder parameters were analysed using regression analysis examining for time trends and correlation to the patient, tumour, or treatment-related factors. Results There was great variability in the mean bladder volumes during the radiotherapy courses (154.17 +/- 129.38 cm3). There were no statistically significant trends for volume changes. Deviations in bladder positions were seen but were small in magnitude. No patient factors were identified which could help predict bladder changes clinically. Bladder variability resulted in a high percentage of fractions (39.6%) in which part of the bladder was outside the PTV. Calculated PTV margins (for 90% of the population to receive 95% of the prescription dose) were 1.48 cm right, 1.15 cm left, 2.13 cm posterior, 1.52 cm anterior, 2.23 cm superior, and 0.52 cm inferior. Conclusions Because of random bladder changes, a significant number of fractions were treated in which the clinical target volume (CTV) fell outside of the PTV. Methods to minimize the amount of CTV that is missed on a fraction to fraction basis should be explored.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.010
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.010
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.324
Teacher spread0.315 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueCureus→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→