Bibliographic record
Abstract
A bstract Quantum radiated power emitted by an Unruh-DeWitt (UD) detector in linear oscillatory motion in (3+1)D Minkowski space, with the internal harmonic oscillator minimally coupled to a massless scalar field, is obtained non-perturbatively by numerical method. The signal of the Unruh-like effect experienced by the detector is found to be pronounced in quantum radiation in the highly non-equilibrium regime with high averaged acceleration and short oscillatory cycle, and the signal would be greatly suppressed by quantum interference when the averaged proper acceleration is sufficiently low. An observer at a fixed angle would see periods of negative radiated power in each cycle of motion, while the averaged radiated power over a cycle is always positive as guaranteed by the quantum inequalities. Coherent high harmonic generation and down conversion are identified in the detector’s quantum radiation. Due to the overwhelming largeness of the vacuum correlators of the free field, the asymptotic reduced state of the harmonics of the radiation field is approximately a direct product of the squeezed thermal states.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".