MétaCan
Menu
Back to cohort
Record W2763237238 · doi:10.1002/rcm.8009

Application of 10 <sup>13</sup> ohm Faraday cup current amplifiers for boron isotopic analyses by solution mode and laser ablation multicollector inductively coupled plasma mass spectrometry

2017· article· en· W2763237238 on OpenAlexaff
Nicholas S. Lloyd, Aleksey Sadekov, Sambuddha Misra

Bibliographic record

VenueRapid Communications in Mass Spectrometry · 2017
Typearticle
Languageen
FieldEarth and Planetary Sciences
TopicGeology and Paleoclimatology Research
Canadian institutionsThermo Fisher Scientific (Canada)
FundersH2020 European Research Council
KeywordsChemistryInductively coupled plasma mass spectrometryBoronMass spectrometryAnalytical Chemistry (journal)Laser ablationPlasmaFaraday cageFaraday cupAmplifierOhmRadiochemistryLaserIonOpticsNuclear physicsOptoelectronicsChromatographyMagnetic fieldIon beamPhysics

Abstract

fetched live from OpenAlex

Rationale Boron isotope ratios (δ 11 B values) are used as a proxy for seawater paleo‐pH, amongst several other applications. The analytical precision can be limited by the detection of low intensity ion beams from limited sample amounts. High‐gain amplifiers offer improvements in signal/noise ratio and can be used to increase measurement precision and reduce sample amounts. Methods 10 13 ohm amplifier technology has previously been applied to several radiogenic systems, but has thus far not been applied to non‐traditional stable isotopes. Here we apply 10 13 ohm amplifier technology for the measurement of boron isotope ratios using solution mode MC‐ICP‐MS and laser ablation mode (LA‐)MC‐ICP‐MS techniques. Precision is shown for reference materials as well as for low‐volume foraminifera samples. Results The baseline uncertainty for a 0.1 pA 10 B + ion beam is reduced to <0.1 ‰ for a typical measurement period. The external precision is better than 0.2 ‰ (2SD) for δ 11 B measurements for solution samples containing as little as 0.8 ng total boron. For in situ microanalyses with LA‐MC‐ICP‐MS, the external precision of 11 B/ 10 B from an in‐house calcite standard was 1 ‰ (2SD) for individual spot analyses, and 0.3 ‰ for the mean of ≥10 replicate spot analyses. Conclusions 10 13 ohm amplifier technology is demonstrated to offer advantages for the determination of δ 11 B values by both MC‐ICP‐MS and LA‐MC‐ICP‐MS for small samples of biogenic carbonates, such as foraminifera shells. 10 13 ohm amplifier technology will also be of benefit to other non‐traditional stable isotope measurements.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.004
Threshold uncertainty score0.013

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0040.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.058
GPT teacher head0.347
Teacher spread0.288 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations43
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueRapid Communications in Mass SpectrometrySame topicGeology and Paleoclimatology ResearchFrench-language works237,207