Balloon Pulmonary Angioplasty for Chronic Thromboembolic Pulmonary Hypertension
Why is this work in the frame?
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
No Canadian affiliation. An affiliation-only frame — the usual design — would never have seen this work. It is one of the works that make the case for inverting the frame.
Machine scores (provisional)
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
- Teacher spread
- 0.256 · how far apart the two teachers sit on this one work
- Validation status
score_only:v0-immature-baseline· verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it
Abstract
BACKGROUND: Balloon pulmonary angioplasty (BPA) is an alternative therapy for patients with chronic thromboembolic pulmonary hypertension who are ineligible for pulmonary endarterectomy-the standard therapy. Currently, most reported results of BPA are from relatively small cohorts treated at single centers. The present study evaluated the safety and efficacy of BPA for chronic thromboembolic pulmonary hypertension based on a multicenter registry. METHODS AND RESULTS: A total of 308 patients (62 men and 246 women; mean age, 61 years) underwent 1408 procedures at 7 institutions in Japan. Data were retrospectively reviewed to evaluate clinical outcome and complications. Hemodynamics were significantly improved in 249 patients in whom BPA was terminated, most often because of improvement in mean pulmonary arterial pressure or symptomatic improvement after 1154 procedures. In 196 patients who underwent follow-up right heart catheterization, improvement of hemodynamic parameters was maintained. Mean pulmonary arterial pressure decreased from 43.2±11.0 to 24.3±6.4 mm Hg after final BPA and 22.5±5.4 mm Hg at follow-up, with significant reduction of concomitant use of pulmonary hypertension-targeted therapy and oxygen supplementation. Complications occurred in 511 (36.3%), including pulmonary injury (17.8%), hemoptysis (14.0%), and pulmonary artery perforation (2.9%). Twelve patients (3.9%) died during follow-up, including 8 patients who died within 30 days after BPA. The leading causes of death were right heart failure, multiorgan failure, and sepsis. Overall survival was 96.8% (95% confidence interval, 93.7%-98.4%) at 1 and 2 years and 94.5% (95% confidence interval, 89.3%-97.3%) at 3 years, respectively, after the initial BPA procedure for all 308 patients. CONCLUSIONS: This multicenter registry suggested improved hemodynamic results after BPA. Complication rates were high, but overall survival was comparable with pulmonary endarterectomy. BPA may be an important therapeutic option in patients with chronic thromboembolic pulmonary hypertension.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
The record
- Venue
- Circulation Cardiovascular Quality and Outcomes
- Topic
- Pulmonary Hypertension Research and Treatments
- Field
- Medicine
- Canadian institutions
- —
- Funders
- Actelion PharmaceuticalsBayer YakuhinBayer CanadaNippon Shinyaku
- Keywords
- MedicinePulmonary hypertensionAngioplastyPulmonary arteryPulmonary embolismSurgeryCardiologyBalloonInternal medicineHeart failurePerforation
- Has abstract in OpenAlex
- yes