MétaCan
Menu
Back to cohort
Record W2766441513 · doi:10.1002/lio2.120

Elements of virtual temporal bone surgery: Manipulandum format may be more important to surgeons than haptic device force capabilities

2017· article· en· W2766441513 on OpenAlexaff
Bertram Unger, Nariman Sepehri, Vivek Rampersad, Justyn Pisa, Michael Gousseau, Jordan Hochman

Bibliographic record

VenueLaryngoscope Investigative Otolaryngology · 2017
Typearticle
Languageen
FieldMedicine
TopicSurgical Simulation and Training
Canadian institutionsHealth Sciences CentreUniversity of Manitoba
Fundersnot available
KeywordsHaptic technologyDrillComputer scienceFidelityVirtual realityComputer visionHigh fidelityDegrees of freedom (physics and chemistry)Artificial intelligenceSimulationEngineeringAcousticsPhysicsTelecommunications

Abstract

fetched live from OpenAlex

Background Temporal bone simulations are critiqued for poor drill‐bone interaction. This project appraises the import of increasing haptic device and manipulandum fidelity on the perceived realism of drilling a virtual temporal bone. Virtual surgical contact forces rely on haptic device fidelity and are transmitted through a manipulandum. With identical software, both device hardware and manipulandum may each contribute to realism. We compare the three degrees of freedom (DOF), 3N Geomagic Touch (3D Systems, SC) to a 6DOF, 5.5N HD2 (Quanser, ON) with the both standard (“HD2–Standard”) and in‐house customized otic drill manipulandum (“HD2–Modified”). Methods Six otologic surgeons performed three virtual mastoidectomy surgeries on a temporal bone surgical simulator. The HD2 manipulandum was modified for attached otic drill with gravity compensation and requisite mechanical modifications. Surgeons, in random order, performed the dissection with the different hardware platforms. Results Two‐tailed t‐tests demonstrate that for the acoustic properties of each simulation, the HD2–Modified manipulandum was favored (p ≤ 0.0004). For overall similarity of bone, both HD2–Standard (p ≤ 0.05) HD2–Modified (p ≤ 0.03)) were favored over the Geomagic; however they were not appreciably different when directly compared to each other. There was no preference for increasing haptic device fidelity in virtual drill bone interaction. In forced rank, users favored the HD2–Modified in osseus, vibrational and overall realism, as well as being preferred for education and preoperative rehearsal (p ≤ 0.0164). Conclusion Increasing manipulandum realism was favored. However surprisingly, there was no preference for increased device fidelity, illustrating incremental stiffness had nominal impact. There may be a ceiling to drill bone interaction in virtual haptic simulation. Level of Evidence 2b.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.009
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.008
Threshold uncertainty score0.026

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.009
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0080.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.067
GPT teacher head0.324
Teacher spread0.257 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueLaryngoscope Investigative OtolaryngologySame topicSurgical Simulation and TrainingFrench-language works237,207