MétaCan
Menu
Back to cohort
Record W2768446634 · doi:10.5301/ijao.5000657

Fluid structure interaction model analysis of cerebrospinal fluid circulation in patients with continuous-flow left ventricular assist devices

2017· article· en· W2768446634 on OpenAlexaff
Jessica G.Y. Luc, Clifford Pierre, Kevin Phan, Yashar Seyed Vahedein, Alexander S. Liberson, William K. Cornwell, Steven J. Phillips, Vakhtang Tchantchaleishvili

Bibliographic record

VenueThe International Journal of Artificial Organs · 2017
Typearticle
Languageen
FieldEngineering
TopicMechanical Circulatory Support Devices
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsCerebrospinal fluidVentricular assist deviceMedicineCardiologyInternal medicineBlood flowFlow (mathematics)Fluid–structure interactionPulse (music)MechanicsHeart failurePhysics

Abstract

fetched live from OpenAlex

PURPOSE: The current 1-dimensional fluid structure interaction model (FSI) for understanding cerebrospinal fluid (CSF) circulation requires pulsatility as a precondition and has not been applied to patients with continuous-flow left ventricular assist devices (CF-LVAD) where pulsatility is chronically reduced. Our study aims to characterize the behavior of CSF pressure and flow in patients with CF-LVADs using a computational FSI model. METHODS: Utilizing the computational FSI model, CSF production in choroid plexuses of the 4 ventricles was specified as a boundary condition for the model. The other source of production from capillary ultrafiltrate spaces was accounted for by the mass conservation equation. The primary CSF absorption sites (i.e., arachnoid granulations) were treated as the outlet boundary conditions. We established a low pulse wave to represent patients with a CF-LVAD. RESULTS: From the model, low pulse conditions resulted in a reduction in CSF pressure amplitude and velocity though the overall flow rate was unchanged. CONCLUSIONS: The existing FSI model is not a suitable representation of CSF flow in CF-LVAD patients. More studies are needed to elucidate the role of pulsatility in CSF flow and the compensatory changes in CSF production and absorption that occur in patients with CF-LVADs in whom pulsatility is diminished.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.094
Threshold uncertainty score0.412

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.238
Teacher spread0.227 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueThe International Journal of Artificial OrgansSame topicMechanical Circulatory Support DevicesFrench-language works237,207