MétaCan
Menu
Back to cohort
Record W2772734918 · doi:10.3390/mi8120353

Electrical Tweezer for Droplet Transportation, Extraction, Merging and DNA Analysis

2017· article· en· W2772734918 on OpenAlexaff
Ali Shahid, Sylvia Chong, James B. Mahony, M. Jamal Deen, P. Ravi Selvaganapathy

Bibliographic record

VenueMicromachines · 2017
Typearticle
Languageen
FieldEngineering
TopicElectrowetting and Microfluidic Technologies
Canadian institutionsSt. Joseph’s Healthcare HamiltonMcMaster University
Fundersnot available
KeywordsMicrofluidicsOil dropletNanotechnologyElectrowettingAqueous solutionAqueous two-phase systemElectric fieldChemistryMaterials scienceMerge (version control)Chemical physicsOptoelectronicsEmulsionPhysics

Abstract

fetched live from OpenAlex

Droplets of aqueous solutions distributed in an immiscible oil phase are increasingly used and investigated as a means to handle and assay small volumes of samples. The primary attraction of this method is that surface interactions are kept to a minimum, and changes in sample concentration, especially due to adsorption to the walls, are avoided. Microfluidic methods to generate, transport, merge, split and perform reactions in droplets were developed recently. These methods depend on the continuous flow of the two phases involved inside closed microfluidic channels. Alternatively, an electrowetting phenomenon was also exploited to control the movement of droplets between two solid substrates. However, there are some situations where small volume sample transport and assaying are required in open systems. Here, we demonstrate a simple electromechanical probe (tweezers) that is capable of manipulating a small aqueous droplet in a bi-layer oil phase. The tweezer consists of two needles positioned close to each other and uses polarization of the aqueous droplet in an applied electrical field to confine the droplet between the needles with minimal solid contact. Mechanical motion of the tweezer can be used to transport the droplet to various positions. Operations such as aliquoting, merging and transport are demonstrated. Finally, this method was used to perform a DNA amplification assay where droplets of the sample and the amplification mixture are aliquoted separately, mixed and amplified using an in-situ heater. This electromechanical tweezer is of interest in low-throughput, small-volume biological and chemical assays where the investigator requires direct and open access to the samples.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.004
Threshold uncertainty score0.014

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0040.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.249
Teacher spread0.243 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueMicromachinesSame topicElectrowetting and Microfluidic TechnologiesFrench-language works237,207