A high-pressure metallic core holder for magnetic resonance based on Hastelloy-C
Bibliographic record
Abstract
A metallic core holder, fabricated from non-magnetic Hastelloy-C276, has been designed for Magnetic Resonance (MR) and Magnetic Resonance Imaging (MRI) of core plug samples at high pressures and temperatures. Core plug samples, 1.5″ in diameter and 2″ in length, can be tested in the core holder at elevated pressures and temperatures, up to 5000 psi and 80 °C. These are conditions commonly found in petroleum reservoirs. A radio frequency probe, which excites and detects magnetic resonance signals, was placed inside the metal vessel. Proximity to the sample improves the signal to noise ratio of the resulting measurements. The metallic core holder is positioned between the poles of a 0.2 T permanent magnet and subjected to rapidly switched magnetic field gradients as part of the imaging process. This switching induces eddy currents on the conductive core holder, which degrades the magnetic field gradient waveform in the sample space. The low electrical-conductivity of Hastelloy-C276 minimizes the duration and the magnitude of such eddy currents. A recently developed pre-equalization technique was employed to ensure that magnetic field gradient pulses, required for MRI, are near ideal in the sample space. A representative core flooding experiment was undertaken in conjunction with MR/MRI measurements.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.001 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".