Assessment of a ventilator circuit adapter to be used in conjunction with the Respimat* Soft Mist Inhaler (SMI)

2017· article· en· W2776194161 on OpenAlexaff
Jason Suggett, Mark Nagel

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldMedicine
TopicInhalation and Respiratory Drug Delivery
Canadian institutionsTrudell Medical International (Canada)
Fundersnot available
KeywordsAdapter (computing)MedicineAnesthesiaSalbutamolInhalerBiomedical engineeringComputer scienceComputer hardwareInternal medicineAsthma

Abstract

fetched live from OpenAlex

Rationale: With the introduction of the Respimat* SMI there is a desire for an adapter to allow its use in ventilator circuits. An adapter (RespiConnect*) was assessed in terms of drug delivery and safety features. Methods: The adapter contains a self-sealing valve and safety cap intended to prevent loss of airway pressure and maintain a closed ventilator circuit. The adapter was assessed for its ability to retain circuit integrity as well as aerosol drug delivery. Each adapter (n=10) was inserted in the inspiratory limb of a heated adult circuit. A 7.0 mm ET tube was attached to a filter and the distal side of the filter coupled to an adult test lung to simulate a patient. Ventilation (600-mL, I:E 1:3, 10 BPM) was created by a Siemens 900C. Five actuations of Combivent® SMI were delivered, each actuation followed by 6 complete breathing cycles. Between actuations the SMI was removed from the adapter and primed according to manufacturer’s instructions. Salbutamol (SAL) and ipratropium (IPR) were recovered from the filter and quantified by HPLC as % label claim (LC). Results: During the experiment the circuit did not lose pressure and no alarms were triggered, indicating that the self sealing valve was effective. Mean values of 30.3% and 29.4% LC were determined for SAL and IPR respectively. Conclusions: Approximately 30% LC of both drug components in the SMI was delivered to the distal end of ET tube via the adapter. The presence of a self-sealing valve and safety cap for the adapter should ensure ventilator circuit integrity and therefore also help protect the safety of the patient.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.053
GPT teacher head0.324
Teacher spread0.271 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2017
Admission routes1
Has abstractyes