MétaCan
Menu
Back to cohort
Record W2777553653 · doi:10.1097/prs.0000000000004216

Capsular Biofilm Formation at the Interface of Textured Expanders and Human Acellular Dermal Matrix: A Comparative Scanning Electron Microscopy Study

2017· article· en· W2777553653 on OpenAlexaff
Michel Alain Danino, Johnny Ionut Efanov, Georges Dimitropoulos, Maxim Moreau, Charles Maalouf, Monica Nelea, Ali Izadpanah, Jean‐Philippe Giot

Bibliographic record

VenuePlastic & Reconstructive Surgery · 2017
Typearticle
Languageen
FieldMedicine
TopicBreast Implant and Reconstruction
Canadian institutionsUniversité de MontréalHôpital Notre-Dame
Fundersnot available
KeywordsScanning electron microscopeBiofilmMaterials scienceBiomedical engineeringMatrix (chemical analysis)Electron microscopeChemistryComposite materialMedicineOpticsBiologyBacteria

Abstract

fetched live from OpenAlex

BACKGROUND: Despite benefits in reducing capsular contractures, textured implants have been associated with significant pitfalls, such a propensity for biofilm formation. Few studies have investigated whether the use of acellular dermal matrix on textured implants produces similar findings. This study aims to characterize biofilm formation at the capsular-acellular dermal matrix interface with scanning electron microscopy. METHODS: The authors performed a prospective observational pilot study in patients undergoing two-stage expander-to-permanent implant exchange. Patients were inflated with Biocell or Siltex expanders, and specimens from the capsular-pectoralis interface and capsular-acellular dermal matrix interface were obtained and examined under scanning electron microscopy for capsular ingrowth and biofilm formation using the Van Herdeen Biofilm Grading System and the Biofilm Thickness Grading Scale. RESULTS: Nine patients including 14 breasts (28 capsular samples in total) were examined. Thick biofilm formation was observed in all specimens from the capsular-acellular dermal matrix interface with Biocell and 25 percent of capsule-pectoralis interface, whereas no biofilm formation was found in Siltex implants. For Biocell implants, a significant difference in biofilm coverage between the upper and lower poles was observed using the Van Herdeen Biofilm Grading System (p = 0.0028) and the Biofilm Thickness Grading Scale (p = 0.0161). CONCLUSIONS: Biocell implants produce a significant rate of biofilm formation over acellular dermal matrix-covered capsules, which is not present in the muscular region or in Siltex implants. Further randomized controlled trials will further elucidate the clinical impact of using acellular dermal matrices with macrotextured implants. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.242
Threshold uncertainty score0.739

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0010.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.332
Teacher spread0.302 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations25
Published2017
Admission routes1
Has abstractyes

Explore more

Same venuePlastic & Reconstructive SurgerySame topicBreast Implant and ReconstructionFrench-language works237,207