MétaCan
Menu
Back to cohort
Record W2782056198 · doi:10.1093/europace/eux290

Safety and long-term effectiveness of paroxysmal atrial fibrillation ablation with a contact force-sensing catheter: real-world experience from a prospective, multicentre observational cohort registry

2018· article· en· W2782056198 on OpenAlexaff
Tom De Potter, Hugo Van Herendael, Richard Balasubramaniam, Matthew Wright, Sharad Agarwal, Prashanthan Sanders, Yaariv Khaykin, D. G. Latcu, Philippe Maury, Antonio Pani, John Hayes, Jonathan M. Kalman, Pablo B. Nery, Edward Duncan

Bibliographic record

VenueEP Europace · 2018
Typearticle
Languageen
FieldMedicine
TopicAtrial Fibrillation Management and Outcomes
Canadian institutionsUniversity of OttawaSouthlake Regional Health Center
FundersBiosense WebsterSt. Jude Medical
KeywordsMedicineAtrial fibrillationConfidence intervalCatheter ablationObservational studyAblationInternal medicineOdds ratioProspective cohort studyCohortQuality of life (healthcare)Clinical endpointSurgeryCardiologyRandomized controlled trial

Abstract

fetched live from OpenAlex

Aims: Real-time contact force (CF)-sensing radiofrequency ablation catheter for treatment of paroxysmal atrial fibrillation (PAF) allows optimization of electrode-tissue contact, which correlates with long-term success. This prospective, multicentre observational registry assessed the real-world clinical effectiveness of a CF-sensing catheter for ablation of drug-refractory PAF. Methods and results: Patients were followed-up at 3, 6, and 12 months after ablation. Outcome measures included isolation of targeted pulmonary veins (PVs) confirmed by entrance block (acute success), patient-reported freedom from symptomatic atrial fibrillation (AF) at 12 months (long-term effectiveness), Atrial Fibrillation Effect on Quality-of-life scores at 6 and 12 months, and incidence of predefined procedural complications. The registry enrolled 261 PAF patients (mean age 58.8 ± 11.3 years; 70.7% men; 91.7% Caucasian). Acute PV isolation was reported in 98.8% of patients [95% confidence interval (CI): 96.4-99.7%], and 12-month success for freedom from symptomatic AF was 75.7% (95% CI: 69.7-80.7%). Average CF for the evaluable cohort was 16.4 ± 3.9 g. There was a significant correlation between long-term effectiveness and stability of CF use [percentage of time CF was within investigator-selected working range; odds ratio (95% Wald CI), 1.0 (1.00-1.1); P = 0.030]. Average CF did not correlate with 12-month success. Clinically meaningful quality of life (QoL) improvements were observed at 6 and 12 months. Primary adverse events occurred in 2.7% patients. Conclusion: This observational registry showed that PAF ablation with a CF-sensing catheter had high acute success rates, favourable 12-month outcomes, and a good safety profile. Patients' QoL improved significantly. Long-term effectiveness significantly correlated with stable CF with adequate catheter-tissue contact (NCT01677052).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.589

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.035
GPT teacher head0.315
Teacher spread0.280 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations25
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueEP EuropaceSame topicAtrial Fibrillation Management and OutcomesFrench-language works237,207