Safety and long-term effectiveness of paroxysmal atrial fibrillation ablation with a contact force-sensing catheter: real-world experience from a prospective, multicentre observational cohort registry
Bibliographic record
Abstract
Aims: Real-time contact force (CF)-sensing radiofrequency ablation catheter for treatment of paroxysmal atrial fibrillation (PAF) allows optimization of electrode-tissue contact, which correlates with long-term success. This prospective, multicentre observational registry assessed the real-world clinical effectiveness of a CF-sensing catheter for ablation of drug-refractory PAF. Methods and results: Patients were followed-up at 3, 6, and 12 months after ablation. Outcome measures included isolation of targeted pulmonary veins (PVs) confirmed by entrance block (acute success), patient-reported freedom from symptomatic atrial fibrillation (AF) at 12 months (long-term effectiveness), Atrial Fibrillation Effect on Quality-of-life scores at 6 and 12 months, and incidence of predefined procedural complications. The registry enrolled 261 PAF patients (mean age 58.8 ± 11.3 years; 70.7% men; 91.7% Caucasian). Acute PV isolation was reported in 98.8% of patients [95% confidence interval (CI): 96.4-99.7%], and 12-month success for freedom from symptomatic AF was 75.7% (95% CI: 69.7-80.7%). Average CF for the evaluable cohort was 16.4 ± 3.9 g. There was a significant correlation between long-term effectiveness and stability of CF use [percentage of time CF was within investigator-selected working range; odds ratio (95% Wald CI), 1.0 (1.00-1.1); P = 0.030]. Average CF did not correlate with 12-month success. Clinically meaningful quality of life (QoL) improvements were observed at 6 and 12 months. Primary adverse events occurred in 2.7% patients. Conclusion: This observational registry showed that PAF ablation with a CF-sensing catheter had high acute success rates, favourable 12-month outcomes, and a good safety profile. Patients' QoL improved significantly. Long-term effectiveness significantly correlated with stable CF with adequate catheter-tissue contact (NCT01677052).
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".